正压检漏法在密封舱整体漏率设计及检测中的应用 被引量:2

Application of Positive Pressure Leak Detection in Design and Testing of Integral Leak Rate of Capsule
下载PDF
导出
摘要 该文应用罩盒累积提高正压检漏法的检漏灵敏度,应用该检漏方法识别出影响密封舱整体漏率的薄弱环节,针对薄弱环节采取结构形式改进和密封圈材料更换等方法提高对接面处密封性能,从而达到降低密封舱整体漏率的目的。 An encloser is used to improve accumulatively the detection sensitivity of positive pressure leak detection and identify the weak points which may affect the integral leak rate of the capsule in this paper. Some methods, such as structural improvement and change of sealing ring material are taken to improve the sealing ability at the mating surface against the weak points, thus to reduce the integral rate of capsule.
出处 《科技创新导报》 2015年第22期159-160,187,共3页 Science and Technology Innovation Herald
关键词 密封舱 氦质谱检漏 正压检漏 整体漏率 局部漏率 Capsule Helium mass-spectrometer leak detection Positive pressure leak detection Integral leak rate Local leak rate
  • 相关文献

参考文献3

  • 1崔民生.浅谈大容器的氦质谱检漏工艺方法[C]//第二届全国真空检漏技术工业应用研讨会论文集.北京:中国真空学会,2000:49-51.
  • 2张启亮,谷京华,朱秀珍,陈旭,查良镇,李明蓬.正压氦质谱检漏灵敏度的校准和微流量的测量[J].真空,1996,33(2):25-31. 被引量:13
  • 3王亚军,吴孝俭,等.气罩积分法正压检漏的候检时[日][C].第九届全国质谱分析与检漏会议论文集,1997(8).