摘要 设计了一种亲水改性的管式海水淡化实验装置,对其进行了常压定温加热实验和不同介质气体条件下的实验研究,分析了淡化装置产水性能及其影响因素。不同运行温度的实验研究表明,亲水改性型管式淡化装置的产水率随运行温度的提高而增加,当运行温度为80℃时,产水率达到最高为0.15 L/h,比光滑管式淡化装置的产水率提高了约20%。不同介质气体条件下的实验结果表明,采用CO_2或O_2等分子量大的介质气体,与Air为介质气体相比,可以较好的提高装置的稳态产水性能。 A tubular desalination still by hydrophilic modification was designed. Under the conditions of given temperature and different kinds of medium gas, aseries of experimental research were conducted to analyzethe water production performance of the device and its factors. The results showed that water production rate per hour increased as temperature rose, reaching 0.15 L/h when temperaturewas 80℃, approximately 20% more than that of the unmodified still. The still with carbon dioxide or oxygen as the medium gas displayed a better performance in steady water production than that with air. Using medium gas with larger molecular weight could improve the water production performance.
出处 《水处理技术》 CAS CSCD 北大核心 2015年第12期73-76,共4页 Technology of Water Treatment
基金 太阳能多效管式蒸馏热质传递机理(51106177) 中国博士后一等资助(2013M540208)
关键词 亲水改性 海水淡化 换热管 hydrophilic modification desalination heat exchange tube
  • 相关文献

参考文献5

  • 1边志明,张蕾.中国水资源存在的主要问题及合理开发利用新理念[J].环境科学与管理,2011,36(10):147-153. 被引量:17
  • 2Chen Z L, Yao Y, Zheng Z H, et al. Analysis of the characteris-tics of heat and mass transfer of a three-effect tubular solar still and experimental research[J].Desalination,2013,330:42-48.
  • 3李斌彬,徐宏,张莉,任彬.表面改性高效热管传热性能实验研究[J].石油化工设备,2015,44(1):5-8. 被引量:4
  • 4Huang D J, Leu T S. Condensation heat transfer enhance-ment bY surface modification on a monolithic copper heat sink [J].Applied Thermal Engineering,2015,75:908-917.
  • 5Takata Y, Hidaka S, Cao J M, et al. Effect of surface wettability on boiling and evaporation[J].Energy,2010,30(2-4):209-220.

二级参考文献22

共引文献18

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部