摘要
针对电机软启动器频繁发生的故障停机现象进行深入分析、总结,提出预判及处理方法,以保证快速有效地排除故障,增加设备运行可靠性。
After commissioning the soft starter had frequently broken down. Through deepened analysis and conclusion of the phenomenon, a pre-judgment and treatment method was put forward, to ensure fast and effective diagnosis of the fault and improve the operation reliability of the equipment.
出处
《冶金动力》
2015年第12期9-10,共2页
Metallurgical Power
关键词
软启动器
停机故障
功率单元
电阻
电压
soft starter
shutdown fault
power unit
resistance