摘要
地铁车站在建设及使用中会产生渗漏水,造成车站积水、混凝土溶蚀、钢筋骨架锈蚀等,严重影响结构的耐久性和可靠性。文章就常见地铁车站的典型渗漏水现象进行归类分析,并对渗漏水预防提出设计、施工工艺及质量等方面的防控措施建议。
In metro station, water leakage occurs in both the construction period and the operational period, causing station surface water ponding, concrete corrosion, corrosion of reinforced steel, seriously affecting the structure durability and reliability. The paper classifies and analyzes the common seepage and leakage phenomenon in metro stations, and puts forward some recommendations on counter measures in the preventive design, construction technologies and quality control.
出处
《现代城市轨道交通》
2015年第6期56-58,65,共4页
Modern Urban Transit
关键词
地铁车站
渗漏水
防控措施
metro station, seepage and leakage, control measures