低浓度等渗对比剂和低管电压扫描在320排CT肺动脉成像中的应用 被引量:6

Application of“Double low”in 320-row CT pulmonary angiography
下载PDF
导出
摘要 目的探讨低浓度等渗对比剂和低管电压的"双低"模式行320排CT肺动脉成像的图像质量和辐射剂量。方法 42例行肺动脉CTA患者随机分为两组:A组20例,使用120kV管电压,优维显370mgI/ml对比剂;B组22例,采用100kV管电压,碘克沙醇270mgI/ml对比剂,其余参数设置相同。测量每例患者肺动脉主干和分支的CT值,计算图像信噪比和对比噪声比。记录设备自动生成的剂量长度乘积,计算有效剂量。应用独立样本的t检验对上述数据进行统计学分析。结果两组图像质量均符合诊断要求,两组肺动脉各段CT值、图像信噪比和对比噪声比差异均无统计学意义(P>0.05)。使用120kV组的剂量长度乘积和有效剂量高于100kV组,差异有统计学意义(P<0.05)。结论应用碘克沙醇270mgI/ml对比剂、100kV管电压结合迭代重建行320排CT肺动脉成像,图像质量能满足临床诊断要求,且有效地降低了辐射剂量。 Objective To evaluate image quality and radiation dose under low concentration of contrast agent and low tube voltage for pulmonary angiography(CTPA)by using of 320-row CT with a"double low"scanning protocol.Methods42 patients,who underwent pulmonary angiography(CTPA)with a 320 CT scanner,were divided into two groups randomly.20patients(group A)received 120 kV voltage and ultravist(370mgI/ml),and the remaining 22patients(group B)received 100 kV voltage and iodixanol(270mgI/ml).The rest of parameter settings was consistent.We evaluated the CT value of the pulmonary artery trunk and branches in each case and determined image signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR).Then,we recorded dose length product and calculated the effective radiation dose.The all above data were subjected to statistical analsis using two independent sample t test.Results Image quality of two groups were conformed to the requirements of diagnosis.The CT value,SNR,and CNR of each pulmonary artery had no significant difference between two groups(P〉 0.05).The dose length product and the effective radiation dose of group A were higher than group B,and there were statistically significant difference between them(P〈 0.05).Conclusion Image quality of CTPA by the scanning protocol(100kV+iodixanol,270mgI/ml)of 320-row CT scanner can meet the requirement of clinical diagnosis,and effectively reduce the radiation dose.
出处 《医学影像学杂志》 2015年第11期1933-1935,共3页 Journal of Medical Imaging
关键词 肺动脉 对比剂 辐射剂量 体层摄影术 X线计算机 Pulmonary artery Contrast agent Radiation dose Tomography X-ray computed
  • 相关文献

参考文献7

二级参考文献43

  • 1崔锦泰.小波分析导论[M].西安:西安交通大学出版社,1995..
  • 2Alkadhi H,Scheffel H,Desbiolles L,et al.Dual-source computed tomography coronary angiography:influence of obesity,calcium load,and heart rate on diagnostic accuracy[J].Eur Heart J,2008,29:766-776.
  • 3Brenner D J,Hall EJ.Computed tomography:an increasing source of radiation exposure[J].N Engl J Med,2007,357:2277-2284.
  • 4From AM,Bartholmai B J,Williams AW,et al.Mortality associated with nephropathy after radiographic contrast exposure[J].Mayo Clin Proc,2008,83:1095-1100.
  • 5Leipsic J,Labounty TM,Heilbron B,et al.Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography:the ERASIR study[J].AJR Am J Roentgenol,2010,195:655-660.
  • 6Leipsic J,Labounty TM,Heilbron B,et al.Adaptive statistical iterative reconstruction:assessment of image noise and image quality in coronary CT angiography[J].AJR Am J Roentgenol,2010,195:649-654.
  • 7Oda S,Utsunomiya D,Funama Y,et al.A low tube voltage technique reduces the radiation dose at retrospective ECG-gated cardiac computed tomography for anatomical and functional analyses[J].Acad Radiol,2011,18:991-999.
  • 8Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease.Report of the Ad Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery,American Heart Association[J].Circulation,1975,51:5-40.
  • 9Earls JP,Berman EL,Urban BA,et al.Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique:improved image quality and reduced radiation dose[J].Radiology,2008,246:742-753.
  • 10Miller JM,Dewey M,Vavere AL,et al.Coronary CT angiography using 64 detector rows:methods and design of the multi-centre trial CORE-64[J].Eur Radiol,2009,19:816-828.

共引文献86

同被引文献53

引证文献6

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部