期刊文献+

血管超声检查在PICC置管中的应用 被引量:3

Vascular Ultrasound Examination on the Application of PICC Catheter
下载PDF
导出
摘要 目的 探析血管超声检查在PICC置管中的应用效果。方法 选取2014年1月-2015年8月我院收治的157例PICC置管患者为研究资料,所有患者在进行PICC置管过程中均给予血管超声检查,对所有患者的超声检查结果及其临床应用价值进行回顾性分析。结果 经检查,157例PICC置管患者中,0级血管102例,Ⅰ级血管35例,Ⅱ级血管12例,Ⅲ级血管8例;经超声检查显示,显示为颈内静脉导管异位15例,未显示颈内静脉导管异位142例。结论 在PICC置管中应用血管超声检查可检测出导管异位的情况,提高穿刺成功率。 Objective To analysis the efficacy of vascular ultrasound examination on the application of PICC catheter. Methods From January 2014 to August 2015,157 cases of patients with PICC catheter for research materials inour hospital,all of the patients were performed in the process of PICC catheter vascular ultrasound,ultrasonic examination results of all patients were retrospectively analyzed and its clinical application value. Results Examined 157 patients with PICC catheter,the level 0,102 cases of vessels,Ⅰ vascular 35 cases,Ⅱ vascular 12 cases,Ⅲ magnitude 8 cases of blood vessels,the ultrasound examination showed that show,15 cases of internal jugular vein catheter heterotopia not shown 142 cases of internal jugular vein catheter heterotopia. Conclusion The application of vascular ultrasound in PICC catheter can detect the catheter heterotopia,improve the success rate of puncture,therefore.
作者 梁国胜
出处 《中国卫生标准管理》 2015年第22期174-175,共2页 China Health Standard Management
关键词 血管超声检查 PICC置管 应用效果 Vascular ultrasound PICC catheter Application effect
  • 相关文献

二级参考文献36

  • 1范育英,胡雯,黄蔚华.106例超声引导下结合微插管鞘行PICC置管术的临床效果[J].当代护士(下旬刊),2010,17(12):114-115. 被引量:8
  • 2郭丽娟,张鸿雁,赵晓玉,于淑芹,赵书彦.超声技术在预防PICC所致血栓中的应用[J].护理学杂志(综合版),2005,20(7):33-34. 被引量:68
  • 3杜华.湿热敷预防PICC致机械性静脉炎的效果观察[J].中国实用护理杂志,2005,21(12):7-8. 被引量:140
  • 4胡君娥,龚兰,唐运香,张强,周娟.彩超及B-FLOW技术引导下经外周静脉穿刺中心静脉置管的可行性研究[J].护理学报,2007,14(6):5-7. 被引量:22
  • 5Nichols I,Hamphrey JP.The Efficacy of Upper Arm Placement of Peripherally Inserted Central Catheters Using Beside Ultrasound and Microintroducer Technique[J].Journal of Infusion Nursing,2008,31(4):165-176.
  • 6McMahon D D.Evaluation new technology to improve patient outcomes:A quality improvement approach[J].Journal of Infusion Nursing,2002,25(4):250-255.
  • 7Mitsufuii N, Matsuo K, Kakila S, el al. Extravascular colh,ction of fluid anmnd the verttebra rt'sulting f'rom malposilioning of a periph- erally inserted central venous catheter in extremely low birth weightl infants [ J ] . Pe ri nat Med, 2002,30 ( 4 ) : 341-344.
  • 8江群,廖丽,阳静,等.662例PICC导管尖端定位的研究[J].中国健康,2011,30(1):53-54.
  • 9Abdullah B J, Mohammad N, Sangkar J V al. huidcn of upper- limb venous thrombosis associated with peripherally ;nslttqt tlli atheters ( P1CC ) [ J ]. Br J Radio1,2005,7B ( 931 ) :596-600.
  • 10Gonsalves CF, Flchelmtm DJ ,Sullivan Kh,el al. Im'idence of ml- tral vein slenosis and occlusim followi:g upper ,pxlremily PICC mg port placement[J],rdiovtlsc hllervent Radiol, 2003,2,5 ( 2 ) : 123-127.

共引文献22

同被引文献20

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部