摘要
根据AP1000核电机组的特点,结合核电设备的安全性、可靠性、技术合理性和经济性要求,从变压器的容量、结构、冷却方式和调压方式等方面对主变等变压器选型进行了分析和比较。
According to the characteristics of AP1000 nuclear power plant, combining the safety, reliability, technical rationality and economic requirements of nuclear power plant, this paper analyzes and compares the transformer's capacity, structure, cooling mode and the way of adjusting and pressing.
出处
《科技与创新》
2015年第23期92-93,共2页
Science and Technology & Innovation
关键词
变压器
调压方式
冷却方式
核电机组
transformer
voltage regulation
cooling mode
nuclear power plant