摘要
介绍了新开车的离子膜法烧碱生产装置及其运行情况,针对装置开车初期脱氯系统亚硫酸钠消耗偏高的情况,提出了降低脱氯系统亚硫酸钠消耗的改进措施。
A facility newly started up for production of ion-exchange membrane caustic soda was intro-duced as well its running situations. Excess sodium chloride was consumed in dechlorination at the early stage of start-up. Improvement measures to reduce sodium sulfite consumption were proposed.
出处
《氯碱工业》
CAS
2015年第11期3-6,共4页
Chlor-Alkali Industry
关键词
离子膜法电解
烧碱
生产装置
脱氯系统
亚硫酸钠
ion-exchange membrane electrolysis
caustic soda
production facility
dechlorination system
sodium sulfite