摘要
分析了VGSP1000型离心式氯气压缩机组振值超标的原因,提出了相应的处理措施。处理后,取得了良好的效果。
The causes of excessive vibration of VGSP1000 type centrifugal chlorine compressor unit were analyzed and the corresponding treatment measures were put forward. Good results were obtained after treatment.
出处
《氯碱工业》
CAS
2015年第11期36-37,共2页
Chlor-Alkali Industry
关键词
氯气压缩机
振动
转子
动平衡
chlorine compressor
vibration
rotor
dynamic balance