摘要
本文对铁路电力系统使用无功补偿方式的现状进行了分析,对无功补偿装置不同类型的特点和优缺点做了简要介绍和比对,在此基础上,对茶坞配电所自闭线路现有无功补偿方式和存在的问题进行了分析,提出了茶坞配电所自闭线路无功补偿解决方案。
This paper analyzed the current situation of reactive power compensation mode in railway power system, and introduced and compared the features and advantages and disadvantages of different types of the reactive power compensation device. On this basis, the way of reactive compensation for the self-closing power supply system in Chawu distribution substation and the existing problems are analyzed, and puts forward the solution.
出处
《价值工程》
2016年第1期112-114,共3页
Value Engineering
关键词
配电所
供电系统
无功补偿
distribution substation
power supply system
reactive power compensation