能谱CT评价射频消融治疗非小细胞肺癌的早期疗效 被引量:2

CT spectral imaging evaluation of early efficacy of radiofrequency ablation in treatment of non-small cell lung cancer
下载PDF
导出
摘要 目的探讨CT宝石能谱成像(GSI)在射频消融治疗非小细胞肺癌(NSCLC)早期疗效评价中的应用价值。方法收集经临床和病理证实的NSCLC患者20例,其中腺癌12例,鳞癌8例。于射频消融治疗前和治疗后早期(<1个月)进行能谱CT扫描,获得肺动脉期图像,并进行图像重建,得到碘基物质图像、水基物质图像、70 keV水平的单能量CT值及能谱曲线斜率,并对治疗前后进行对比分析。结果 20例患者病灶射频消融治疗后的碘(水)基含量、70 keV水平CT值、能谱曲线斜率明显低于治疗前,水(碘)基含量略高于治疗前,差异均有统计学意义(P均<0.05)。结论 GSI可反映NSCLC射频消融治疗前后病灶的血供特点及灌注程度变化,有助于评价射频消融治疗NSCLC的早期疗效。 Objective To evaluate the value of gemstone spectral imaging(GSI) in early evaluation of emcacy of radiofrequency ablation(RFA) therapy of non-small cell lung cancer(NSCLC).Methods Twenty patients with NSCLC were confirmed by clinic and pathology,which included 12 cases of adenocarcinoma,8 cases of squamous carcinoma.All the patients were preformed GSI respectively before treatment and early after treatment(〈1 month).By using images of the pulmonary artery phase and GSI viewer reconstruction software,the images were reconstructed.The iodine-substance images,water-based image,70 keV energy CT value and energy spectrum curve slope were acquired,and the differences of these parameters before and after treatment were statistically analyzed.Results The iodine(water) content,70 keV energy CT value and energy spectrum curve slope of the lesions after RFA treatment were lower than those before treatment,and water(iodine) content was slightly higher than that of before treatment,the differences were all statistically significant(all P〈0.05).Conclusion GSI can reflect changes of blood supply and perfusion degree of NSCLC before and after RFA therapy,which is heloful to evaluating the early efficacy of radiofrequency ablation in the treatment of NSCLC.
出处 《中国医学影像技术》 CSCD 北大核心 2015年第12期1840-1843,共4页 Chinese Journal of Medical Imaging Technology
关键词 非小细胞肺 导管消融 宝石能谱成像 Carcinoma non-small-cell lung Catheter Ablation Gemstone spectral imaging
  • 相关文献

参考文献17

二级参考文献99

  • 1彭泽华,蒲红,董丹丹,白林,陶克言,黄红云,张晓军,付凯,赵世煜.周围型肺癌的CT征象与VEGF和MVD表达的相关性研究[J].医学影像学杂志,2005,15(3):195-198. 被引量:8
  • 2刘春秋,李振家,窦卫涛,韩旭健,王险峰,于香红.CT导向下射频消融治疗不能手术切除肺癌患者的临床分析[J].医学影像学杂志,2012,22(2):205-207. 被引量:13
  • 3张金娥,梁长虹,赵振军,林华欢,曾辉,何晖,茹光腾.CT肺灌注在肺结节诊断中的应用研究[J].中华放射学杂志,2005,39(10):1041-1045. 被引量:95
  • 4王同权,魏晓东,李宏杰,路伟.X射线的衰减和能量沉积计算[J].原子能科学技术,2007,41(4):399-403. 被引量:20
  • 5Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovohage switching: improved image quality as compared with that obtained with conventional 120 kVp CT. Radiology, 2011 ,In press.
  • 6Lv P, Lin XZ, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced soectral CT method. Radioloav. 2011. In nress.
  • 7Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr, 2011, 35:294-297.
  • 8Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol, 2011, In press.
  • 9Feuerlein S, Roessl E, Proksa R, et al. Muhienergy photoncounting K-edge imaging: potential for improved luminal depiction in vascular imaging. Radiology, 2008, 249 : 1010-1016.
  • 10Pan D, Roessl E, Schlomka JP,et al. Computed Tomography in color: nanok-enhanced spectral CT molecular imaging. Angew Chem Int Ed Engl,2010, 49:9635-9639.

共引文献487

同被引文献24

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部