文中从变电站运行实际出发,描述了变电站高压设备的感应放电现象。针对变电站高压设备存在的感应放电现象,定性的分析了感应放电的产生机理与微观发展过程,以隔离开关为研究对象利用Ansoft Maxwell电磁场仿真软件解得了感应放电的边界条件。通过对放电电路网络的分布参数进行计算,利用Oracle PSpice电路仿真软件解得了单个感应放电脉冲所带来的的电能损耗,以电场与电路仿真相结合的方式,参考变电站实际运行规律及社会用电量等统计数据,估算出变电站高压设备感应放电所产生的电能损耗。
Derived from practical operation of power substation, the phenomenon of high voltage apparatus inductive discharge is illustrated. The initiating principle and microcosmic proceeding of inductive discharge is qualitatively demonstrated. A disconnecting switch is set as researching model and Ansoft Maxwell is utilized to determine the boundary conditions of inductive discharge. Distribution parameters are introduced to form a circuit model for quantitative estimation of electric power loss. Using Oracle PSpice, the power loss is accurately estimated. Utilizing field-circuit combined analysis, referring the practical operation rules of power substation, national power consumption and relative statistical data, the total power loss of inductive discharge is concisely estimated.
出处
《高压电器》
CAS
CSCD
北大核心
2015年第12期103-108,共6页
High Voltage Apparatus
关键词
变电站
感应放电
场路结合分析
仿真
电能损耗
substation
inductive discharge
field-circuit combined analysis
simulation
power loss