摘要
该文设计了一种电解电容器漏电流的测量方法,利用是德科技34401A型数字繁用表可快速确定电解电容器漏电流,大量节省测量时间,有效提高测试工作效率。并通过相应的测量不确定度评价分析,证明该方法可以满足GB/T 2693-2001《电子设备用固定电容器第1部分总规范》的要求。
This paper designs an electrolytic capacitor leakage current measurement method,using 34401 A digital multimeter to quickly determine the leakage current of electrolytic capacitors can be used,save a lot of time measurement,effectively improve the work efficiency of the test And through the corresponding measurement uncertainty evaluation analysis,it is proved that this method can meet the requirements of GB/T2693- 2001 fixed capacitors for use in electronic equipment Part one:Generic specification.
出处
《电子质量》
2015年第12期19-22,共4页
Electronics Quality
关键词
电解电容器
漏电流
数字繁用表
不确定度
Electrolytic capacitors
leakage current
Digital multimeter
Uncertainty