摘要 简要介绍了大型喷洒塔的功能组成,介绍了喷洒塔云雾参数标定的目的,给出了云雾参数标定方法,制定了标定流程,最后给出了部分标定结果,并对结果进行了分析,提出了建议。 The components and function of the icing spray tower were introduced briefly first. Then the purpose of the freezing frog parameters calibration was expressed. The method of calibration was provided. The flow of calibration was formulated. At last, some results of calibration were provided. Based on the results, some conclusions were obtained, some proposals were suggested.
出处 《直升机技术》 2015年第4期58-62,共5页 Helicopter Technique
关键词 喷洒塔 云雾参数 标定 icing spray tower freezing frog parameters calibration
  • 相关文献

参考文献4

  • 1Bellucci M, Esposito B M. Calibration of the CIRA IWT in the Low Speed Configuration [ C]. 45th AIAA Aero- space Sciences Meeting and Exhibit.
  • 2SAE - ARP5905, Calibration and Acceptance of Icing Wind Tunnels [ S ]. 2003.
  • 3易贤,桂业伟,杜雁霞,朱国林,李军.结冰风洞水滴直径标定方法研究[J].实验流体力学,2010,24(5):36-41. 被引量:14
  • 4PDI Flight Probe, Dual Range (FPDR) User Manual [Z].