期刊文献+

曝气沉砂池与二氧化氯发生器的节能降耗技术

Technology of Energy-Conservation and Consumption-Reduction for Aerated Grit Chamber and Chlorine Dioxide Generator
下载PDF
导出
摘要 该文主要通过调节曝气沉砂池罗茨鼓风机的频率以及二氧化氯发生器的原料配比,达到节能降耗的目的。以石井污水处理厂的关键辅助设施为研究对象,对实施项目期间的能耗、药耗进行了分析。结果表明当罗茨风机的频率为35 Hz时,砂粒附着有机物(COD)的去除率高达18.53%;沉砂池分离出的砂粒平均纯净度最佳,基本稳定在90%以上;与最大频率时相比可节约能耗1.77 k W。二氧化氯发生器原料氯酸钠与盐酸的最佳配比为1∶3.2时,转化率最高,生产1 kg二氧化氯的总成本至多可以节约11.4元。 Roots blower frequency of aerated grit chamber and raw material ratio of chlorine dioxide were adjusted to achieve the goal of reducing the energy consumption in this paper, based on the critical support facilities of shijing sewage treatment plant. Besides, energy consumption, chemical agent consumption and tons of water cost of this program were analyzed. The results show that when the roots blower frequency is adjusted to 35 Hz, removal rate of organics on the sand can reach 18.53%, and sand purity is the highest, which stay stable at 90%. Meanwhile, roots blower frequency at 35 Hz can save 1.77 kW than the maximum frequency. When the ratio of sodium chlorate and hydrochloric acid is 1 : 3.2, the conversion rate of chlorine dioxide is the highest and the total cost of producing 1 kg chlorine dioxide can save at most 11.4 yuan.
出处 《净水技术》 CAS 2015年第6期81-84,89,共5页 Water Purification Technology
基金 2013年广州市水务科技项目(GZSWKJXM2013-01)
关键词 曝气沉砂池 二氧化氯 能耗 药耗 节能降耗 aerated grit chamber chlorine dioxide energy consumption chemical consumption energy-conservation and consumption -reduction
  • 相关文献

参考文献8

二级参考文献18

  • 1范文雯,蔡群兴.二氧化氯在污水处理中的应用[J].安徽科技,2004(6):35-35. 被引量:4
  • 2吕乃熙.曝气沉砂池的适用条件[J].给水排水,1993,19(3):15-19. 被引量:2
  • 3许劲,孙俊贻,周幸儒,罗留念.不设初沉池时沉砂池的选型分析[J].重庆建筑大学学报,2005,27(2):61-64. 被引量:18
  • 4李君文,于祚斌,战威,高明.水中二氧化氯、氯及亚氯酸根的区分测定研究[J].中华预防医学杂志,1994,28(4):230-232. 被引量:14
  • 5[2]Marc M H,Susanna K,Thomas A T,et al.Oxidation of pharmaceuticals during water treatment with chlorine dioxide[J].Warter Research,2005(39):3607-3617.
  • 6[3]Raczyk-Stanislawiak,Swietlik J,Dabrowska A,et al.Biodegradability of organic by-products after natural organic matter oxidation with ClO2-case study[J].Water Research,2004(38):1045-1054.
  • 7国家环保总局《水和废水监测分析方法》编委会.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002.156-161.
  • 8.生活饮用水卫生规范[Z].[S].卫生部卫生法制与监督司,2001..
  • 9Kolar J. J. lindgen B. O. Spectrophotometric determination of chlorine dioxide in the presence of chlorine[J]. Tappi Journal. 1983.67(8) :81
  • 10消毒技术规范.第3版、第1分册[s],实验技术规范,中华人民共和国卫生部,1999