摘要 针对变送风温度的变风量空调系统,提出了一种简化的双线性控制算法.此控制算法可以在送风温度大幅度波动的情况下,将室内温度维持在设定值.利用TRNSYS软件建立仿真平台,对简化的双线性控制算法进行测试,结果表明:简化的双线性控制可以获得比传统的比例积分(PI)控制更好的控制结果,简化的双线性控制算法可以很好地应用到变送风温度的变风量空调系统中,提高室内温度控制的鲁棒性. In variable air volume (VAV) air-conditioning system, space temperature control becomes difficult when the supply air temperature is uncontrolled and fluctuates significantly. For this kind VAV air-conditioning system, a simplified bilinear feedback control algorithm was developed. This control algorithm can maintain the space temperature to the set point well although the supply air tem- perature fluctuates with large range. The software of transient simulation program (TRNSYS) was used to develop a simulation platform to test the simplified bilinear feedback control algorithm. The test results show that the simplified bilinear control algorithm has a better control performance than conventional PI control. Therefore, the simplified bilinear control algorithm can be applied to VAV air-conditioning system with the variable supply air temperature to improve the robustness of the space temperature control very well.
出处 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2015年第12期86-89,105,共5页 Journal of Huazhong University of Science and Technology(Natural Science Edition)
基金 国家自然科学基金资助项目(51178201) 中央高校基本科研业务费专项资金资助项目(2015QN116) 高等学校博士学科点专项科研基金资助项目(20120142110078)
关键词 变风量空调系统 变送风温度 双线性控制 鲁棒性 动态仿真 variable air volume (VAV) air-conditioning system variable supply air temperature bi-linear control robustness dynamic simulation
  • 相关文献

参考文献12

  • 1Cakir U, Comakli K, Ytiksel F. The role of cogener- ation systems in sustainability of energy[J]. Energy Conversion ~ Management, 2012, 63(11): 196-202.
  • 2RAC Engineers. ASHRAE Handbook of Fundamen- tals[M]. Atlanta: American Society of Heating, Re- {rigeradng and Air-Conditioning Engineers Inc, 2009.
  • 3Huang G S, Filip J. Model-based robust temperature control for VAV air-conditioning system[J]. HVAC~R Research, 2012, 18(3):432-445.
  • 4Huang G S. Model predictive control of VAV zone thermal systems concerning bi-linearity and gain non- linearity[J]. Control Engineering Practice, 2011, 19 700-710.
  • 5Huang G S, Wang S W. Two-loop robust MPC for the temperature control of air-handling units [J]. HVAC~R Research, 2008, 14(4).. 565-580.
  • 6Astrom K J, Hagglund T. PID controllers., theory, design and tuning[M]. Chapel Hill: Instrument Soci- ety of American, 1995.
  • 7Thompson R, Dexter A L. A fuzzy decision-making approach to temperature control in air-conditioning systems[J]. Control Engineering Practice, 2005, 13 (6) : 689-698.
  • 8Morosan P D, Bourdais R, Dumur D, et al. Building temperature regulation using a distributed model pre- dictive control[J]. Energy and Buildings, 2010, 42: 1445-1452.
  • 9Anderson M, Buehner M, Young P, et al. MIMO ro- bust control of HVAC systems[J].IEEE Transac- tions on Control Systems Technology, 2008, 16: 475- 483.
  • 10Wang S W, Ma Z J. Supervisory and optimal control of building HVAC systems: a review [ J ]. HVAC~R Research, 2008, 14(1) : 3-32.