期刊文献+

堆芯混凝土样品中^(63)Ni的分析测量

Measurement of ^(63)Ni in Concrete Samples in Reactor
下载PDF
导出
摘要 为建立堆芯混凝土材料中^(63)Ni活度测量的方法,进行了溶样方法的确定、淋洗曲线的绘制、液闪测量效率的确定、回收率实验、去污实验及空白实验等方面的研究工作。混凝土样品磨至粒径小于0.074mm,用混合酸(V(HNO_3)∶V(HClO_4)∶V(HF)=3∶2∶1)进行溶解,再通过阴离子交换分离、氢氧化物沉淀及萃取和反萃等样品纯化程序去除杂质离子后,用液体闪烁能谱仪测量其中^(63)Ni的活度。该方法的化学回收率为73.05%,放化回收率为71.99%,通过空白实验得出计数的标准偏差为0.200/s,相对标准偏差为12.8%(n=12),方法检出限为3.596Bq/g。该方法可应用于堆内混凝土材料及非堆材料中63 Ni的常规监测及应急监测。 In order to develop a new method of measuring 63 Ni in concrete samples of reactor, these study were done, including the ways of dissolving the samples, drawing the elution curve, the measurement efficiency, recovery tests, decontamination experiments and blank tests. Samples were ground to 0. 074 mm and were pretreated before liquid scintillation counting(LSC) by leaching with mixed acid (V(HNO3) : V(HC104) : V(HF)=3: 2 : 1), anion exchange, hydroxide precipitation, and solvent extraction. The chemical yield of this method is 73.05%, and the radiochemical yield of this method is 71.99%. The standard de- viation is 0. 200/s and the relatively standard deviation is 12.8% (n= 12). The detection limit of the method is 3. 596 Bq/g. This method can be applied to the routine and emergency moni- toring for 63 Ni of the concrete materials in or not in the reactor.
出处 《核化学与放射化学》 CAS CSCD 北大核心 2015年第6期457-462,共6页 Journal of Nuclear and Radiochemistry
关键词 混凝土 放化分析 63Ni 液闪测量 concrete radiochemical analysis 63 Ni liquid scintillation counting
  • 相关文献

参考文献8

  • 1Scheuerer C, Schupfner R. A very senstive LSC procedure to determine Ni 63 in environmental sam ples, steel and concrete [J]. J Radioanal Nucl Chem, Articles, 1995, 193(1).. 127-131.
  • 2Mellado J, Tarancon A. Combination of chemical separation and data treatment {or 5s Fe, 6a Ni, 99 Tc, a7 Cs and 0 Sr/90y activity determination in radioac- tive waste by liquid scintillation[J]. Appl Radiat Isot, 2005(63): 207- 215.
  • 3Hou Xiaolin, Ostergaard L F, Nielsen S P. Deter- mination of 63 Ni and ss Fe in nuclear waste samples using radiochemical separation and liquid scintilla- tion counting[J]. Anal Chim Acta, 2005, 535: 297- 307.
  • 4翟盛庭,冯静毅,孔祥蓉,吴勋群,沈峰.反应堆构件中^(63)Ni的分离和自动测量[J].核动力工程,1995,16(1):88-93. 被引量:8
  • 5余耀仙.水中..Ni含量的测量[J].辐射防护,1988,8(2):146-150.
  • 6Radwan M, Przybylska A, Mykowska E, et al. Meas urernent of nickel-63 low activity in samples of metals and alloys with the help of liquid scintillators[J]. Int J Appl RadiatIsot, 1981, 32: 97-99.
  • 7王萍,邱永梅,吴涛,谭昭怡,但贵萍,孙宇.反应堆铝合金样品中^(63)Ni测定的前处理技术研究[J].原子能科学技术,2010,44(B09):128-133. 被引量:4
  • 8卢瑛,班莹.金属材料中^(63)Ni的测定[J].核化学与放射化学,2000,22(1):45-49. 被引量:9

二级参考文献18

  • 1翟盛庭,沈峰.自动绝对测量^(99)Tc活度[J].原子能科学技术,1994,28(3):241-245. 被引量:4
  • 2翟盛庭,冯静毅,孔祥蓉,吴勋群,沈峰.反应堆构件中^(63)Ni的分离和自动测量[J].核动力工程,1995,16(1):88-93. 被引量:8
  • 3SCHEUERER C,SCHUPFNER R.A very sensitive LSC procedure to determine Ni-63 in environmental samples,steel and concrete[J].J Radioanal Nucl Chem,1995,93(1):127-131.
  • 4MELLADO J,TARANCON A.Combination of chemical separation and data treatment for 55Fe,63Ni,99Tc,137Cs and 90Sr/99Y activity determination in radioactive waste by liquid scintillation[J].Applied Radiation and Isotopes,2005,63:207-215.
  • 5HOU Xiaolin,φSTERGAARD L F,NIELSEN S P.Determination of 63Ni and 55Fe in nuclear waste samples using radiochemical separation and liquid scintillation counting[J].Analytica Chimica Acta,2005,535:297-307.
  • 6余耀仙.水中镍-63的测量.辐射防护,1988,8(2):146-150.
  • 7RADWAN M,PRZYBYLSKA A,MYKOWSKA E,et al.Measurement of nickel-63 low activity in samples of metals and alloys with the help of liquid scintillators[J].Int J Appl Radiat Isot,1981,32:97-99.
  • 8赵敏,班莹.水中铁-59的测定[R].北京:原子能出版社,1993.
  • 9翟盛庭,沈峰,楼滨乔.通用自动计数与数据处理装置及应用[J]核电子学与探测技术,1992(02).
  • 10翟盛庭,王依华.Ys-01多功能液体闪烁测量装置及其高的能量分辨率特性[J]核动力工程,1987(04).

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部