摘要 研究了GIL发生击穿性放电时对母线外壳表面产生振动信号的特征,以及使用振动信号进行GIL发生击穿性放电定位的方法及机理。对振动传感器的选型、振动信号的数据采集、振动信号的传输通信机制、振动信号处理的关键算法、传输与分析的软硬件设计和上位机设计进行了较为详细的描述。 This paper has conducted a srudy on the vibration signal characleristics on the bus shell surface as GILsuffers a breakdown discharge, and the method and mechanism to position the breakdown discharge on GIL by vibration signal. It also gives a more detailed description on the lectolype of vibrating sensor, data acquisition of vibration signals, transmission communication mechanism of vibration signal and key algorithms for vibration signal processing, design of hardware and software for transmission and analysis and design of host computer.
出处 《上海电气技术》 2015年第4期33-37,55,共6页 Journal of Shanghai Electric Technology
关键词 GIL 击穿性放电 振动 压电薄膜传感器 电磁干扰 GIL Breakdown Discharge Vibration Piezoelectric Thin Film Sensor Electromagnetic Interference
  • 相关文献

参考文献11

二级参考文献65

  • 1赵现平.GIS设备绝缘性能检测技术[J].云南电力技术,2006,34(4):9-10. 被引量:17
  • 2肖燕,郁惟镛.GIS中局部放电在线监测研究的现状与展望[J].高电压技术,2005,31(1):47-49. 被引量:142
  • 3侍海军,王光前,张少炎.GIS现场绝缘试验技术[J].高压电器,2005,41(1):55-58. 被引量:33
  • 4李信,李成榕,李亚莎,王伟,李海亮.有限时域差分法对GIS局部放电传播的分析[J].中国电机工程学报,2005,25(17):150-155. 被引量:49
  • 5蒋建玲.用超高频法研究GIS中局部放电的高频特性[R].北京:华北电力大学,2003..
  • 6HOSHINO T, KATO K, HAYAKAWA N, et al. A novel technique for detecting electromagnetic wave caused by partial discharge in GIS. IEEE Trans on Power Delivery, 2001, 16(4) : 545-551.
  • 7MEIJER S, SMIT J J. UHF defect evaluation in gas insulated equipment. IEEE Trans on Dielectrics and Electrical Insulation, 2005, 12(2): 285-296.
  • 8HOSHINO T, KOYAMA H, MARUYAMA S, et al. Comparison of sensitivity between UHF method and IEC 60270 for onsite calibration in various GIS. IEEE Trans on Power Delivery, 2006, 21(4): 1948-1953.
  • 9SAKAKIBARA T, MURASE H, HAGENOMORI E, et al. Study of propagation phenomena of partial discharge pulses in gas insulated substation. IEEE Trans on Power Delivery, 1998, 13(3): 768-776.
  • 10MAEKAWA H, MASUI T, INUJIMA H. Partial discharge locating system for GIS// Proceedings of fEE the 2nd International Conference on Advances in Power System Control,Operation and Management: Vol 1, December 7-10, 1993, Hong Kong, China: 159-163.