期刊文献+

喷射FRP拉伸力学性能的试验与分析 被引量:1

Experiment and analysis of tensile properties of sprayed FRP
下载PDF
导出
摘要 为研究喷射FRP的拉伸力学性能,文中对13组试件进行了单向拉伸力学性能试验,分析其应力—应变曲线、抗拉强度、拉伸弹性模量、断裂伸长率等力学性能指标。研究纤维类型、树脂种类、纤维体积率、纤维长度、试件厚度等因素对喷射FRP力学性能的影响。结果显示:纤维类型和树脂种类对喷射FRP拉伸力学性能的影响十分明显;纤维体积率为20%~25%,纤维长度为40 mm时,喷射FRP能获得较好的力学性能;喷射FRP试件厚度增加并不能持续有效的增强力学性能,不宜过厚。研究表明:为获得较好的力学性能,喷射FRP宜采用碳纤维喷射纱和乙烯基酯树脂加工制作,纤维体积率和长度宜控制在一定范围,且材料厚度不宜过厚。 To study the tensile properties of sprayed FRP,13 groups of specimens were tested for their tensile properties,and the index of stress-strain curve,tensile strength,elastic modulus,elongation and other mechanical properties were analyzed. Influence of fiber type,resin type,fiber volume fraction,fiber length,specimen thickness and other factors on the mechanical properties of sprayed FRP was studied. The results show that the effect of fiber type and resin type on the tensile properties of sprayed FRP is very obvious; that,when the fiber volume fraction is 20% ~ 25% and the fiber length is 40 mm,sprayed FRP demonstrates better mechanical properties; that the mechanical properties of sprayed FRP specimens cannot be effectively enhanced with the increase of the thickness of specimens,and the sprayed FRP should not be too thick. In order to obtain better mechanical properties,sprayed FRP had better be produced by carbon fiber sprayed yarn and vinyl ester resin,the volume ratio and length of fiber should be limited to a certain range,and the thickness of the material should not be too thick.
出处 《广西大学学报(自然科学版)》 CAS 北大核心 2015年第6期1345-1351,共7页 Journal of Guangxi University(Natural Science Edition)
基金 湖北省自然科学基金资助项目(2011CDB232)
关键词 喷射FRP 拉伸力学性能 影响因素 sprayed fiber reinforced polymer tensile mechanical properties influencing factors
  • 相关文献

参考文献8

  • 1LEE H K, HAUSMANN R L, SEAMAN W C. Effectiveness of retrofitting damaged concrete beams with sprayed fiber-rein-forced polymer coating[ J]. Journal of Reinforced Plastics & Composites, 2008, 27(12) : 1269-1286.
  • 2BOYD A J,LIANG N, GREEN PS, et al. Sprayed FRP repair of simulated impact in prestressed concrete girders[ J].Construction and Building Materials, 2008 , 22(3) : 411-416.
  • 3YANG Zhao, WU Cai. Analysis on the seismic performance of RC frame beam-column joints strengthened by sprayed FRP[J]. Applied Mechanics and Materials, 2014,578-579:835-838.
  • 4谷倩,张广海,蒋华,朱飞强.喷射GFRP抗震加固开门洞砌体墙试验研究[J].华中科技大学学报(自然科学版),2011,39(9):102-107. 被引量:6
  • 5GB/T1447-2005纤维增强塑料拉伸性能试验方法[S].北京:中国标准出版社.2005.
  • 6周乾,闫维明,纪金豹,张博.CFRP加固古建筑榫卯节点振动台试验[J].广西大学学报(自然科学版),2011,36(1):37-44. 被引量:11
  • 7BOYD A J. Rehabilitation of reinforced concrete beams with sprayed glass giber reinforced polymers[ D]. Doctoral Thesis,The University of British Columbia, 2000.
  • 8王彬,杨勇新,岳清瑞,李彪.复合理论预测国产碳纤维复合材料筋拉伸强度的离散性研究[J].玻璃钢/复合材料,2014(12):63-67. 被引量:4

二级参考文献12

共引文献23

同被引文献7

引证文献1

二级引证文献5