期刊文献+

Anion Exchange Membranes Based on Chloromethylation of Fluorinated Poly(arylene ether)s

Anion Exchange Membranes Based on Chloromethylation of Fluorinated Poly(arylene ether)s
原文传递
导出
摘要 This report details the properties of fluorine-containing anion exchange membranes(AEMs) synthesized by chloromethylation and quaternization of fluorinated poly(arylene ether)s(FPAEs) based on decafluorobiphenyl and bisphenol A. Meanwhile, we compared their properties with those of their non-fluorinated counterparts, Udel-based AEMs. The reactivity of the chloromethylation of fluorinated poly(arylene ether)s was lowered by the strong elec- tron-withdrawing group, per-fluorinated biphenyl residue. Therefore higher temperature, more chloromethylation reagent, and longer reaction time were needed in the chloromethylation of FPAEs. Because of the hydrophobicity of fluorine, the swelling of FPAEs was depressed. In the FPAE-based AEMs, the water uptake of FPAE-1 membrane(F-1) was just 30%. There is a strong correlation between water uptake and conductivity for both Udel- and FPAE-based AEMs. Among all the membranes, the water uptake and the conductivity of FPAE-3 membrane(F-3) could reach up to 100% and 13.47 mS/cm respectively at 30 ℃. The mechanical properties of FPAE-based AEMs at room tempera- ture were worse than those of Udel-based ones because of the weak intermolecular interaction caused by the low po- larizability of fluorine. However, their high temperature mechanical properties are better, which can be explained in terms of low swelling. This report details the properties of fluorine-containing anion exchange membranes(AEMs) synthesized by chloromethylation and quaternization of fluorinated poly(arylene ether)s(FPAEs) based on decafluorobiphenyl and bisphenol A. Meanwhile, we compared their properties with those of their non-fluorinated counterparts, Udel-based AEMs. The reactivity of the chloromethylation of fluorinated poly(arylene ether)s was lowered by the strong elec- tron-withdrawing group, per-fluorinated biphenyl residue. Therefore higher temperature, more chloromethylation reagent, and longer reaction time were needed in the chloromethylation of FPAEs. Because of the hydrophobicity of fluorine, the swelling of FPAEs was depressed. In the FPAE-based AEMs, the water uptake of FPAE-1 membrane(F-1) was just 30%. There is a strong correlation between water uptake and conductivity for both Udel- and FPAE-based AEMs. Among all the membranes, the water uptake and the conductivity of FPAE-3 membrane(F-3) could reach up to 100% and 13.47 mS/cm respectively at 30 ℃. The mechanical properties of FPAE-based AEMs at room tempera- ture were worse than those of Udel-based ones because of the weak intermolecular interaction caused by the low po- larizability of fluorine. However, their high temperature mechanical properties are better, which can be explained in terms of low swelling.
作者 MEI Wenhai
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2015年第6期1056-1061,共6页 高等学校化学研究(英文版)
基金 Supported by the National Natural Science Foundation of China(Nos.51173178, 514"73157, 21304093).
关键词 Anion exchange membrane Fluorinated poly(arylene ether) CHLOROMETHYLATION Anion exchange membrane Fluorinated poly(arylene ether) Chloromethylation
  • 相关文献

参考文献44

  • 1Dunn B., Kamath H., Tarascon J. M., Science, 2011, 334(6058), 928.
  • 2Zhang H. W., Shen P. K., Chemical Reviews, 2012, 112(5), 2780.
  • 3Diat O., Gebel G., Nat, Mater., 2008, 7(1), 13.
  • 4Hickner M. A., Ghassemi H., Kim Y. S., Einsla B. R., McGrath J. E., Chemical Reviews, 2004, 104(10), 4587.
  • 5Miyatake K., Bae B., Watanabe M, Polymer Chemistry, 2011, 2(9), 1919.
  • 6Bae B., Miyatake K., Uchida M., Uchida H., Sakiyama Y., Okanishi T., Watanabe M., ACS Applied Materials & Interfaces, 2011, 3(7), 2786.
  • 7Shin D. W., Lee S. Y., Kang N. R., Lee K. H., Guiver M. D., Lee Y. M., Macromolecules, 2013, 46(9), 3452.
  • 8Varcoe J. R., Slade R. C. T., Fuel Cells, 2005, 5(2), 187.
  • 9Lu S. F., Pan J., Huang A. B., Zhuang L., Lu J. T., Proceedings of the National Academy of Sciences of the United States of America, 2008, 105(52), 20611.
  • 10Yanagi H., Fukuta K., ECS Transactions, 2008, 16(2), 257.