摘要 以电网遭受雷害多影响因子作为研究重点,采用层次分析与模糊数学相结合理论,对高压电网展开雷害风险评估研究。以某地500 k V高压电网为工程背景,以雷击跳闸率、雷击重合闸率、手动强送成功率、供电可靠性、线路重要性等级、运行时间、设备损害性指标为评估电网雷害风险的分析因子,将该地电网雷害风险等级定为Ⅲ级中等雷害风险,并对此提出针对性的防雷措施,以给工程实际提供指导与借鉴。 The impact factor for power grid subjected to lightning disturbance were taken as the research focus, the hi- erarchical analysis and fuzzy mathematics theory were combined to do the risk assessment study about lightning dis- turbance of high voltage power grid in this paper. Taking a 500 kV high voltage network as the engineering back- ground,the lightning trip-out rate, rate of lightning reclosing, manual forced energization success rate, power supply reliability, line importance level, operation time, equipment damaging and other indexes were analyzed for evaluating power grid lightning risk, and we finally defined the risk level of the power grid in this area was level Ill medium risk. In addition, the corresponding lightning protection measures were put forward, and that can provide guidance and reference to the engineering practice.
作者 强祥
出处 《华北电力技术》 CAS 2015年第12期18-22,共5页 North China Electric Power
关键词 电网雷害 风险评估 层次分析法 模糊数学理论 防雷措施 grid lightning hazard, risk evaluation, analytic hierarchy process, fuzzy mathematics theory, the lightningprotection measures