摘要 分析了线圈杂散参数对高频下复磁导率测量的影响,指出绕组电阻、寄生电容及漏感会导致传统复磁导率测量方法在高频下误差增大。在此基础上提出了使用单匝全包结构进行复磁导率宽带测量的方法,该方法适用于400 MHz以下频率的复磁导率测量。介绍了复磁导率的常见模型,并分别使用Levy法及有理函数迭代逼近法(IRFA)进行模型参数提取,分析了两种算法的优缺点及应用范围。应用推荐复磁导率测量方法对三种磁性材料进行了复磁导率的测量和建模,结果表明,使用推荐的复磁导率测量方法及数据提取算法,可以较好地实现对磁性材料的小信号建模。 Parasite parameters caused by winding have negative impact on broadband complex permeability measurement.This paper identifies the effects of winding resistance,parasite capacitor and leakage inductance.The impact of each parasite parameter is quantitatively determined and an improved measurement method is proposed to mitigate the influence of the parasite parameters.Furthermore,commonly used complex permeability models are introduced.The Levy method and iterative rational function approaching(IRFA)method are used to extract model parameters.The proposed method has been applied to three different kinds of magnetic materials and satisfactory results have been obtained,which conforms the proposed measurement method and parameter extraction algorithms are suitable for building the small-signal model for magnetic materials.
作者 梁涛 谢彦召
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第1期83-88,共6页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(51277148)
关键词 磁性材料 复磁导率 有理函数迭代逼近法 小信号模型 杂散参数 magnetic material complex permeability iterative rational function approaching small signal model parasite parameters
  • 相关文献

参考文献9

二级参考文献72

  • 1韩嵩,杨永伟.加速器驱动的次临界系统快堆次锕系核素非均匀布置堆芯的中子学研究[J].原子能科学技术,2006,40(6):718-722. 被引量:7
  • 2Carter R G. Accm-acy of microwave cavity perturbation measurements [J]. IEEE Trans MTT, 2001, 49(5) : 918- 923.
  • 3Thakur K P, Holmes W S. Dielectric constant and loss factor of dielectric material using finite element method in a cavity [C ]//Microwave Conference, 2000 Asia-Pacific. Tokyo, Japan, 2000 : 116-118.
  • 4Baker-Jarvis J , Vanzura E J , Kissick W A. Improved technique for determining complex permittivity and permeability with the transmission / reflection method [ J ]. IEEE Trans MTT, 1990, 38(8): 1096-1103.
  • 5Nicolson A M , Ross G F. Measurement of intrinsic properties of materials by time-domain techniques [ J ]. IEEE Trans lnstr Meas, 1970, 19(4) : 377-382.
  • 6Barry W. A broad-band, automated, stripline technique for simultaneous measurement of complex permittivity and permeability [J]. IEEE Trans MTT, 1986, 34(1) :80-84.
  • 7Yamaguchi M, Acher O, Miyazawa Y, et al. Cross measurement of thin film permeability up to UHF range [ J ]. J Magn Magn Mat, 2002,242/243/244/245:970-972.
  • 8Bekker V, Seemann K, Leiste H. A new strip line broad- band measurement evaluation for determining the complex permeability of thin ferromagnetic films [ J ] . J Magn Magn Mat, 2004,270(3 ) : 327-332.
  • 9Melville W S.The use of saturable reactor as discharge devices for pulse generators[J].Proc of IEE,1951,9(3):185-205.
  • 10Rukin S N.High power nanosecond pulse generators based on semiconductor opening switch[J].Instruments and Experimental Techniques,1999,42(4):439-467.

共引文献75

同被引文献16

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部