摘要
调速器集油槽油位低低信号误动导致机组跳机,对跳闸逻辑进行优化,文章采用3个信号(低、低低1、低低2)中任意2个动作则出口跳机即所谓3取2模式。
Low signal level governor oilbath misoperation caused a generator, the trip logic optimization, this paper adopts the three signals ( low, low low I, 2 ) any two action is the so-called 3 export jumped 2 mode.
出处
《无线互联科技》
2015年第22期66-67,共2页
Wireless Internet Technology