期刊文献+

高速铁路用新型铜合金接触线电阻温度系数试验研究

Study on Resistance Temperature Coefficient for New-type Copper Alloy Contact Wire for High Speed Railway
下载PDF
导出
摘要 测试高速铁路用新型铜合金接触线在-50℃-150℃范围内的电阻值,通过对得到的"温度—电阻"关系进行线性拟合,得到接触线的电阻温度系数。将该系数与TB/T 2809—2005《电气化铁道用铜及铜合金接触线》和EN 50149:2012中相近接触线的电阻温度系数进行对比,分析其差异性和相似性,提出相应建议,为新型铜合金接触线的产品电阻率检测与工程计算提供依据。 By testing the resistance of new-type copper alloy contact wire for high speed railway within a temperature range of -50℃ -150℃, it can obtain the resistance temperature coefficient of contact wire upon linearly fitting the measured"temperature--resistance"relationship. By comparing the coefficient with the resistance temperature coefficients of similar contact wires as specified in TB/T 2809—2005"Copper and Copper-alloy Contact Wires for Electric Railway"and EN 50149:2012,the article analyses the difference and similarity and gives corresponding suggestions,providing a basis for resistivity testing and engineering calculation of new-type copper alloy contact wire for high speed railway.
出处 《铁道技术监督》 2015年第12期8-10,16,共4页 Railway Quality Control
关键词 铜合金接触线 线性拟合 电阻温度系数 Copper Alloy Contact Wire Linear Fitting Resistance Temperature Coefficient
  • 相关文献

参考文献4

  • 1冯学超,吴杰,蒋逢春,石开,沈岩.金属导体电阻温度系数实验数据处理方法的比较[J].大学物理实验,2014,27(3):114-116. 被引量:5
  • 2GB/T 6148-2005精密电阻合金电阻温度系数测试方法[S].2005.
  • 3EN 50149 : 2012 Railway applications-Fixed installations-Electric traction-Copper and copper alloy grooved contact wires [ S].
  • 4TB/T2809-2005.电气化铁道用铜及铜合金接触线[S].