摘要 文章分析了总氮自动分析仪在地表水监测中的优势与局限。通过对检出限、精密度、准确度等一系列实验室质量要求进行测定发现,该法的空白较低,准确度和精密度均能达到国标要求,分析效率高,但检出限偏高,适合总氮含量较高的地表水监测,对于含量较低的地表水,还应使用传统的国标方法检测。 This paper analyzes the advantages and limitation of total nitrogen automatic analyzer in surface water monitoring . Through a series of laboratory quality experiments, it is founded that this method had a lower blank and the precision and accuracy can meet the requirements of national standard .It's more efficient than the traditional method but the detection limit is higher , so it applies only to higher total nitrogen content of surface water monitoring .Traditional methods of national standard can be used for surface water with lower concentrations.
作者 郎雅娣
出处 《环境科学与管理》 CAS 2015年第8期158-159 183,183,共3页 Environmental Science and Management
关键词 总氮 自动分析仪 监测 total nitrogen automatic analyzer monitoring