摘要 利用De ST软件,对工业厂房中加热设备加热时对空调区域非加热基础车间的基础室温进行模拟与计算,分别计算加热车间在不同排气次数和使用不同厚度的内围护结构时空调区非加热车间的基础室温,并进行比较与分析如何减少加热设备对其他区域的热扰影响。 With the help of DeST software, the room base temperature of non-heating air conditioning area in a tactory building was simulated and calculated by the affect of heating equipment with different exhaust times and thickness of heating workshop's enclosing structure. Finally, the results were used to compare and analyze that how to reduce the thermal disturbance caused by heating equipment.
作者 刘婷 沈致和
出处 《建筑热能通风空调》 2015年第6期61-63,共3页 Building Energy & Environment
关键词 DeST 加热设备 基础室温 热扰 DeST, heating equipment, room base temperature, thermal disturbance
  • 相关文献

参考文献2

  • 1邹月琴,王师白,彭荣,等.高大厂房分层空调负荷计算问题[J].制冷学报,1983(4):49-56.
  • 2赵海.洁净厂房设计规范(GB50073-2013)[S].北京:中国计划出版社,2013.