期刊文献+

列管式光气反应器换热管检测研究 被引量:2

Safety Evaluation of Tube Reactor of Phosgene Reactor
下载PDF
导出
摘要 分析列管式光气反应器换热管的主要失效模式,确定涡流检测方法为最适合的检测手段,本文研究如何提高换热管涡流检测精度,并对3台在用列管式光气反应器换热管开展涡流检测和内窥镜检测,提高了换热管检测精度,检测结果验证了理论分析的正确性。 By analyzing the main failure mode of tube reactor of phosgene synthesis, Eddy current testing is considered as the best method on tube inspection. This paper focuses on the detection accuracy improvement of tube eddy current inspection. We carry out Eddy Current Testing and endoscopy on three tube reactors of phosgene synthesis, during which the detection accuracy of tube eddy current inspection is improved and the result is consistent with theoretical analysis.
出处 《中国特种设备安全》 2015年第12期49-52,共4页 China Special Equipment Safety
关键词 列管式光气反应器 涡流检测 结果分析 Tube reactor of phosgene synthesis Eddy current inspection Analysis of experimental results
  • 相关文献

参考文献5

二级参考文献4

  • 1仲崇立,胡仰栋,周传光,韩方程,赵文明,吕洪杰,孙敦孝,丁建生.光气合成装置流程模拟与设计[J].化学工程,1996,24(5):62-64. 被引量:4
  • 2儿岛邦夫 北原文雄 石黑铁郎.基础物理化学[M].东京:朝仓书店,1984-4..
  • 3E N Shapatina. Kinetics of the catalytics synthesis of phosgene. Kinet Katal[J]. 1977,18(4), 968-972.