期刊文献+

文丘里管内湿天然气流动特性研究进展 被引量:3

The study of the wet gas flow characteristics in venture
下载PDF
导出
摘要 湿天然气计量对于石油天然气工业越来越重要,文丘里流量计由于压力损失小,直管段短,受流型的影响小等优势广泛应用于湿天然气的测量。然而,湿天然气通过文丘里管时,由于液相的存在,使得通过文丘里管时产生的压差值会比等量的气相单独流过时偏高,这种现象称为"虚高"。近几年来国内外研究者对文丘里管湿气测量的虚高进行了大量研究,下面将从实验研究、机理模型研究、数值研究三方面作以简要概述。 The measurement of wet gas is increasingly important for the oil and gas industry.Due to the small pressure loss, short straight sections, little effects by flow patterns and other advantages, venturi meters are widely used in the measurement of wet gas.However,when the wet gas through the venturi, due to the presence of the liquid phase, the differential pressure generated more than the dry gas flow alone,this phenomenon called over-reading.In recent years,domestic and foreign researchers studied the venturi measurements over-reading,following will summarize these researches from the experimental, mechanism model and numerical study.
作者 樊文娟 彭颖
出处 《石油化工应用》 CAS 2015年第12期8-10,14,共4页 Petrochemical Industry Application
关键词 湿天然气 文丘里流量计 流动特性 虚高 wet gas venturi meters flow characteristics over-reading
  • 相关文献

参考文献13

  • 1R.N.Steven.Wet gas metering with a horizontally mounted Venturi meter[J].Flow Measurement and Instrumentation,2002,12(5):361-372.
  • 2J.W.Murdock.Two-phase Flow Measurement With Orifices[J].Journal of Basic Engineering,1962,84:419-433.
  • 3De Leeuw.Wet gas flow measurement using a combination of Venturi meter and a tracer technique[J].North Sea Flow Measurement Workshop,1994.
  • 4Denghui He,Bofeng Bai.Numerical investigation of wet gas flow in Venturi meter[J].Flow Measurement and Instrumentation,2012,28(11):1-6.
  • 5Kum ar Perumal,Jagannathan Krishnan.A CFD study of the effect of venturi geometry on high pressure wet gas metering[J].International Journal of Oil,Gas and Coal Technology,2013,6(5):549-566.
  • 6Ying Xu,Yi Zhao,Zheng Hai Long.Study on the Key Factors of Wet Gas Metering Overreading in Standard Venturi Tube Base on DPM[J].Applied Mechanics and Materials,2012,220-223(12):1693-1697.
  • 7方立德,张涛.Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J].Chinese Journal of Chemical Engineering,2008,16(2):320-324. 被引量:9
  • 8M.van Werven1,H.R.E.van Maanen,G.Ooms et al.Modeling wet-gas annular/dispersed flow through a Venturi[J].Aiche Journal.American Institute of Chemical Engineers,2013,5(6):549-566.
  • 9Peining Yu,Ying Xu,Tao Zhang et al.A study on the modeling of static pressure distribution of wet gas in Venturi[J].Aiche Journal.American Institute of Chemical Engineers,2015,61(2):699-708.
  • 10Fang Lide,Zhang Tao,Xu Ying.Venturi Wet Gas Flow Modeling Based on Homogeneous and Separated Flow Theory[J].Mathematical Problems in Engineering,2006,31(10):10-20.

二级参考文献15

  • 1Agar,J.,Farchy,D.,"Wet gas metering using dissimilar flow sensors:Theory and field trial results",In:SPE Annual Technical Conference and Exhibition,San Antonio,Texas,1-6 (2002).
  • 2Lupeau,A.,Platet,B.,Gajan,P.,Strzelecki,A.,Escande,J.,Couput,J.P.,"influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical con-figuration",Flow Meas.Instrum.,15,1-11 (2007).
  • 3Geng,Y.F.,Zheng,J.W.,Shi,T.M.,"Study on the metering characteristics of a slotted orifice for wet gas flow",Flow Meas.Instrum.,17,123-128 (2006).
  • 4Steven,R.N.,"Wet gas metering with a horizontally mounted venturimeter",Flow Meas.Instrum.,12,361-372 (2002).
  • 5National Engineering Laboratory of UK,"Effects of two-phase flow on single phase flowmeters",Flow Measurement Guidance Note,(3),6,1-3 (1997).http://www.flowprogramme.co.uk/decs/repor ts.asp ?type=6
  • 6Stewart,D.G.,"The evaluation of dry gas meters in wet gas condi-tion",National Engineering Laboratory,London,33-58 (2002).http://www.flowprogramme.co.uk/docs/reports.asp ?rtype= 1
  • 7National Engineering Laboratory of UK,"The evaluation of wet gas metering technologies for offshore application (1) Differential pressure meters",Flow Measurement Guidance Note No.40.2 (2003).http://www.flowprogramme.co.uk/docs/reports.asp?rtype=6
  • 8Btitton,C.,Seidl,W.,Kinney,J.,"Experimental,wet gas data for a Herschel style Venturi",In:5th International Symposium on Fluid Flow Measurement,Arlington,VA (2002).
  • 9Kegel,T.,"Wet gas measurement",Colorado Engineering Experiment Station,Inc.(CEESI) Publications,USA,1-7 (2003).http:/www.ceesi.com/pubs_wetgas.aspx.
  • 10ISO5167-1,"Measurement of fluid flow by mean of pressure differ-ential deices inserted in circular cross-section conduits running full,part 1 General principles and requirements" (2003).

共引文献8