多效新风过滤装置评价体系探讨 被引量:1

Discussion for Evaluation System of Multiple-effect Fresh Air Filter Unit
下载PDF
导出
摘要 一直以来舒适性空调系统的设计是以室外空气是新鲜空气为前提的,因节能的需要,空调设计规范中规定了最小新风量。但由于严重的大气污染,室内引入新风时,必须进行新风过滤处理。目前各种产品繁多,但缺乏系统的多效新风过滤装置的评价体系。污染新风中主要的污染物是颗粒物、SO2、NO2等。本文在分析现有评价体系和指标的基础上,初步探讨了适用于多效新风过滤装置的评价方法和指标。 The pollution of outdoor air is serious, the primary pollutants are PM and SO2, NO2, in addition, bacteria can do harm to our human health. There is hardly a filter in the comfortable air conditioning that can purify all the pollutants mentioned above at the same time, let alone the evaluation system. So the evaluation method need to be established. The author analyzed the existing evaluation system and the comprehensive index, and put forward the evaluation method and comprehensive index that are more suitable for the multiple-effect fresh air filter.
作者 颜静 李振海
出处 《建筑热能通风空调》 2015年第1期90-93,105,共5页 Building Energy & Environment
关键词 多效新风过滤 颗粒物 气态污染物 细菌 测试台 评价标准 综合指标 multiple-effect fresh air filter PM air pollutant bacteria test bench evaluation criterion comprehensive index
  • 相关文献

参考文献13

  • 1程灯塔,刘刚,陆斌.新型驻极体过滤材料在分体空调机上的应用[J].洁净与空调技术,2005(1):26-30. 被引量:7
  • 2高健,王韬,王文兴.中国城市大气超细颗粒物浓度及粒径分布研究[A].中国气象学会2006年年会“大气成分与气候、环境变化”分会场论文集[C].成都:中国气象学会,2006:879-885.
  • 3宋桂香,江莉莉,陈国海,陈秉衡,张蕴晖,赵耐青,蒋颂辉,阚海东.上海市大气气态污染物与居民每日死亡关系的时间序列研究[J].环境与健康杂志,2006,23(5):390-393. 被引量:66
  • 4中国家用电器研究院.GB/T18801空气净化器(草案)[s].
  • 5中国建筑科学研究院.空气净化器污染物净化性能测定(JGff294-2010)[S].北京:中国标准出版社,2011.
  • 6中国建筑科学研究院.空气过滤器(GB/T14295—2008)[S].北京中国标准出版社,2009.
  • 7全国汽车标准化技术委员会.道路车辆乘驾室用空气滤清器(QCT795-2007)[S].北京:中国计划出版社,2008.
  • 8欧洲标准化委员会.一般通风过滤器-过滤性能测定(EN779.2012)[S].2008.
  • 9ASHREA. Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size (ASHREA Stan- dard52.2-2007) IS]. Atlanta: ASHREA, 2007.
  • 10安爱明,秦继恒,王智超,宋灿华.大气尘检测空气过滤器效率不确定因素的分析[J].洁净与空调技术,2008(2):1-6. 被引量:6

二级参考文献28

  • 1中国建筑科学研究院.GB/T14295-93器[S].北京:中国标准出版社,1993.
  • 2中国建筑科学研究院空气调节研究所.空气过滤1999一般通风用空气过滤器性能试验方法[S].北京:中国标准出版社,1999.
  • 3中国建筑科学研究院,北京工业大学,河南省米净瑞发净化设备有限公司,等.GB/T14295--2008空气过滤器[S].北京:中国标准出版社,2009.
  • 4ANSI/ASHRAE. ANSI/ASHRAE Standard 52. 2-1999 Method of testing general ventilation air-cleaning devices for removal efficiency by particle size[S], 1999.
  • 5CEN. EN 779:2002 Particulate air filters for general ventilation--determination of the filtration performances[S], 2002.
  • 6Dominici F.Time-series analysis of air pollution and mortality:a statistical review[J].Res Rep Health Eff Inst,2004,123:3-27.
  • 7Samet JM,Dominici F,Curriero FC,et al.Fine particulate air pollution and mortality in 20 U.S.cities,1987-1994[J].N Engl J Med,2000,343:1742-1749.
  • 8Katsouyanni K,Touloumi G,Spix C,et al.Short-term effects of ambient sulphur dioxide and particulate matter on mortality in 12 European cities:results from time series data from the APHEA project-air pollution and health:a European approach[J].BMJ,1997,314:1658-1663.
  • 9Dominici F,McDermott A,Zeger SL,et al.On the use of generalized additive models in time-series studies of air pollution and health[J].Am J Epidemiol,2002,156:193-203.
  • 10Stieb DM,Judek S,Burnett RT,et al.Meta-analysis of time-series studies of air pollution and mortality:effects of gases and particles and the influence of cause of death,age,and season[J].J Air Waste Manag Assoc,2002,52:470-484.

共引文献85

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部