摘要 胸腰段骨折是临床常见的脊柱损伤,治疗方法比较多,随着后路椎弓根螺钉技术的发展,术后早期椎体高度复位比较满意,但远期随访仍有许多内固定失败的病例。单纯椎弓根螺钉固定术后断钉、断棒、螺钉松动、Cobb角增加等相关并发症发生率高达21%[1-2]。作者2009年9月—2011年5月对收治的15例胸腰段骨折使用经伤椎椎弓根植骨加椎弓根钉复位内固定术治疗,现报告如下。
出处 《实用临床医药杂志》 CAS 2015年第24期152-153,共2页 Journal of Clinical Medicine in Practice
  • 相关文献

参考文献9

  • 1Kirkland B.Wood,Weishi Li,Darren S.Lebl,et al.Management of thoracolumbar spine fractures[J].The spine Journal,2014(14):145.
  • 2张贵林,荣国威,丁占云,姜春岩,吴宏华.脊柱胸腰段骨折术后椎弓根螺钉断裂及弯曲松动的原因分析[J].中华骨科杂志,2000,20(8):470-472. 被引量:282
  • 3Roy-Camille R,Saillant G,Mazel C.Plating of thoracic,thoracolumbar,and lumbar injuries with pedicle screw-plates[J].Orthop Clin North AM,1986,17(1):147.
  • 4Olerud S,Karlstrom G,Sjostrom L.Transpedicular fixation of thoracolumbar vertebral fractures[J].Clin Orthop Relat Res,1988,227(2):44.
  • 5马维虎,徐荣明,冯建翔,周雪杰,俞怡辉,应江炜,薛波.经椎弓根植骨和椎体成形术治疗胸腰椎爆裂性骨折[J].骨与关节损伤杂志,2003,18(8):511-513. 被引量:105
  • 6Ebelke D K,Asher M A,Neff J R,et al.Survivorship analysis of vsp spine instrumentation in the treatment of thoracolumbar and lumbar burst fractures[J].Spine,1991,16:428.
  • 7Golbewskip,Mazarkiewicz T.Preliminary evaluation of the efficacy of transpedicular refilling of spongiosa loss with autologous grafts in thoracolumbar vertebral bodies using the Daniaux method[J].Chir Narzadow Ruchu ortop pol,1999,64:265.
  • 8Mc Cormack T,Karaikovic E,Gaines RW.The load sharing classification of spine fractures[J].Spine(Phila Pa 1976),1994,19(15):1741.
  • 9欧阳钧,陆瓞骥,吕维佳,梁智仁,彭田红.人胸腰椎微骨折与疲劳的关系探讨[J].中华创伤杂志,2000,16(8):463-465. 被引量:4

二级参考文献11

  • 1杨惠林,唐天驷,朱国良,洪天禄,许立,陈荣发,郑祖根.胸腰椎骨折经椎弓根内固定治疗中的失误和并发症的分析[J].中华骨科杂志,1996,16(6):356-359. 被引量:155
  • 2[1]Mclain RF, Sparling E, Benson DR. Early failure of short-segmant pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg (Am), 1993, 75: 162~167
  • 3[2]Ebelke DK, Asher MA, Neff JR, et al. Survivorship analysis of vsp spine instrumentation in the treatment of thoracolumbar and lumbar burst fractures, Spine, 1991, 16:428~432
  • 4[3]Golbewskip, Mazarkiewicz T. Preliminary evaluation of the efficacy of transpedicular refilling of spongiosa loss with autologous grafts in thoracolumbar vertebral bodies using the Daniaux method. Chir Narzadow Ruchuortop pol, 1999, 64:265~271
  • 5[4]Knop C, Fabian HF, Bastian L, et al. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting. Spine, 2001, 26:88~99
  • 6[5]Alanay A, Acarogln E, Yazici M, et al. Short-segment pedicle instrumentation of thoracolurnbar burst fractures: does transpedicular intracorporeal grafting prevent early failure? Spine, 2001, 26:213~217
  • 7[6]Sjostrom L, Jakobsson O, karlstrom G, et al. Transpedicular bone grafts misplaced into the spinal canal. J Orthop Trauma, 1992, 6:376 ~ 378
  • 8[7]Liljenqvist U, Mommsen U. Surgical treatment of thoracolumbar spinal fractures with internal fixator and transpedicular spongiosaplasty. Unfallchirurgie 1995, 21:30~39
  • 9[8]Walchli B, Heini P, Berlemann U. Loss of correction after dorsal stabilization of burst fractures of the thoracolumbar junction. The role of transpedicular spongiosa plasty. Unfallchirurg 2001, 104: 742 ~747
  • 10杨惠林,中华骨科杂志,1996年,16卷,356页

共引文献382

同被引文献147

  • 1Plaats AVD,Veldhuizen AG,Verkerke GJ.Numerical Simulation of Asymmetrically Altered Growth as Initiation Mechanism of Scoliosis.Ann Biomed Eng.2007;35(7):1206-1215.
  • 2Ibarz E,Herrera A,Más Y,et al.Development and kinematic verification of a finite element model for the lumbar spine:application to disc degeneration.Biomed Res Int.2013;2013:705185-705185.
  • 3Polikeit A,Ferguson SJ,Nolte LP,et al.Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages:finite element analysis.Eur Spine J.2002;12(4):413-420.
  • 4Goel VK,Monroe BT,Gilbertson LG,et al.Interlaminar shear stresses and laminae separation in a disc.Finite element analysis of the L3-L4 motion segment subjected to axial compressive loads.Spine.1976;20(6):689-698.
  • 5Ding JY,Qian S,Wan L,et al.Design and finite-element evaluation ofa versatile assembled lumbar interbody fusion cage.Arch Orthop Trauma Surg.2010;130(4):565-571.
  • 6Song C,Li XF,Liu ZD,et al.Biomechanical assessment of a novel L4/5 level interspinous implant using three dimensional finite element analysis.Eur Rev Med Pharmacol Sci.2014;18(18):86-94.
  • 7Duan Y,Wang HH,Jin AM,et al.Finite element analysis of posterior cervical fixation.Orthop Traumatol Surg Res.2015;101(1):23-29.
  • 8Gómez FS,Lorza RL,Bobadilla MC,et al.Study of Different Biomaterials for Artificial Lumbar Disc Prosthesis Using FEM.Appl Mech Mat.2015;(2015):483-487.
  • 9Yamamoto I ,Panjabi MM,Crisco T,et al.Three-dimensional movements of the whole lumbar spine and lumbosacral joint.Spine.1989;14(11):1256-1260.
  • 10Charosky S,Moreno P,Maxy P.Instability and instrumentation failures after a PSO:a finite element analysis.Eur Spine J.2014;23(11):2340-2349.

引证文献15

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部