临床血钾检测结果呈季节性波动的原因分析

Analysis of the Cause of Clinic Serum Potassium Testing Result Presenting Seasonal Fluctuation
下载PDF
导出
摘要 为探讨临床血钾检测结果呈现季节性波动的原因,收集2012年1月——013年12月在我院住院患者的血钾检测结果,统计不同季节血钾检验结果的波动情况,同时,随机抽取2014年1月——2月门诊血钾检验标本100份,分别在12℃与30℃条件下保存2 h后离心分离检测血钾水平。发现血钾检验结果呈现季节性波动,温度较低季节(春冬季节)血钾检测结果偏高,温度较高季节(夏秋季节)检测结果偏低,季节间比较差异显著(P<0.05);12℃下保存2 h离心分离检测血钾水平显著高于30℃下保存2 h测定结果(P<0.05)。说明临床血钾检测结果存在季节性波动表现,在低温下保存可引起血钾检测结果偏高,临床检验中应根据不同季节的变化特点合理选择保存途径。 The aim of this paper is to discuss the cause of seasonal fluctuation that clinic serum potassium represented. Methods of collecting serum potassium testing results of inpatients from January, 2012 to December, 2013 in our hospital and counting the fluctuation of serum potassium testing results in different seasons to achieve this objective were made. Meanwhile, 100 serum potassium testing samples of outpatients from January to February in 2014 were selected randomly. Keeping them in 12 ℃ and 30 ℃ respectively for two hours and then testing the level of serum potassium with centrifugal separation. The result of serum potassium testing represented seasonal fluctuation that the level of serum potassium on the high side in lower temperature seasons(spring and winter) and on the low side in higher temperature seasons(summer and autumn). The comparison of seasons had significant difference(P〈0.05). The level of serum potassium of the samples kept in 12 ℃ for two hours in centrifugal separation detection was remarkably higher than that of in 30 ℃(P〈0.05). The results showed that clinic serum potassium testing results represented seasonal fluctuation and the level of testing results were on the high side when serum potassium samples were kept in low temperature. So serum potassium samples of clinical testing should be kept in reasonable ways according to characteristics of different seasons.
作者 乔晓红
出处 《黑龙江科学》 2015年第18期14-15,共2页 Heilongjiang Science
关键词 血钾 检验结果 波动原因 Serum potassium Testing result Cause of fluctuation
  • 相关文献

参考文献8

二级参考文献41

  • 1李燕平.重视分析前质量控制提高检验质量[J].中华检验医学杂志,2005,28(2):219-219. 被引量:84
  • 2张立平.生化分析仪样品盘上标本放置时间对结果的影响[J].临床检验杂志,1995,13(5):253-253. 被引量:12
  • 3周新,涂植光.临床生物化学和生物化学检验[M].第3版.北京:人民卫生出版社,2006:57.
  • 4松崎广子.血清分离胶[J].检查ぅ技术,1994,22(12):643-645.
  • 5黄守林.血清分离胶在临床生化检验中的应用观察.医学检验与临床,2009,20(5):185-186.
  • 6Lippi G, Blanckaert N,Bonini P,et al. Haemolysis:an overview of the leading cause of unsuitable specimens in clinical laboratories [J]. Clin Chem Lab Med,2008,46(6) :764-772.
  • 7周新.检验医学考核指南[M].武汉:湖北科学技术出版社,2003:511-515.
  • 8毛雪萍.正确留取标本与检验质量的关系[J],中国临床医药研究杂志,2002,12(2):8374-8375.
  • 9周雪艳,陈忠.血液放置时间对化学检测结果的影响[J].国外医学临床生物化学与检验学分册,2006,27(1):48-49.
  • 10杨在春.新编医学数据手册[M].北京:金盾出版社,2002:91-93.

共引文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部