摘要 讨论医疗IT系统应用中集中监控系统的设计、UPS与医疗IT系统的结合应用、IT系统断路器的选型,以及不同医疗场所医用隔离电源柜的安装等相关问题,强调医疗IT系统的设计与施工应标准化、规范化。 The design for the centralized monitoring system, combination of UPS with medical IT system, type selection of circuit breaker for IT system, installation of medical isolated power cabinet in different medical locations and other issues relating to the application of medical IT system are researched, the standardization and normalization is emphasized on the design and construction of medical IT system.
作者 顾方红 徐军
出处 《建筑电气》 2015年第12期21-24,共4页 Building Electricity
关键词 医疗场所 IT系统 集中监控系统 UPS应用 断路器选型 隔离电源柜 绝缘监测装置 对地绝缘电阻 medical locations IT system centralized monitoring system UPS application type selection of circuit breaker isolated power cabinet insulation monitoring devices insulation resistance to earth
  • 相关文献

参考文献7

  • 1吴恩远,马名东,徐军.IT系统在医疗场所的应用及绝缘监测功能扩展[J].建筑电气,2010,29(4):19-22. 被引量:14
  • 2王厚余.论IT系统的应用[J].建筑电气,2008,27(11):3-7. 被引量:34
  • 3中机中电设计研究院,等.GB16895.24-2005/IEC60364-7-710:2002建筑物电气装置第7-710部分:特殊装置或场所的要求医疗场所[S].北京:中国标准出版社,2006.
  • 4中国建筑设计研究院.JGJ312-2013医疗建筑电气设计规范[S].北京:中国建筑工业出版社,2013.
  • 5沈阳变压器研究所.GB19212.16-2005电力变压器、电源装置和类似产品的安全第16部分:医疗场所供电用隔离变压器的特殊要求[S].北京:中国标准出版社.2006.
  • 6上海电器科学研究所(集团)有限公司,等.GB14048.2-2008/IEC60947-2:2006,IDT低压开关设备和控制设备第2部分:断路器[S].北京:中国标准出版社.2008.
  • 7山东建筑电气情报网,安科瑞电气股份有限公司.ACRl2CDX601医疗隔离电源监控系统设计与应用图集[M],2015.