期刊文献+

多管程微通道冷凝器热力性能计算方法 被引量:4

In-tube heat transfer performance calculation of condensing zone in micro-channel condenser
原文传递
导出
摘要 多管程平行流微通道冷凝器的管程设计方案对换热器管内热力性能影响较大。针对各管程工质流量可变、平均干度可变的多管程平行流冷凝器管内热力参数提出一种分程计算方法:在假设管壁温度不变及同管程内流量均匀分配的前提下,采用Koyama和Wang提出的冷凝传热模型,以及Zhang和Koyama提出的摩擦压降模型,建立了壁温与热流量之间的关系式,通过迭代求得管内平均传热系数和压降的理论值。以一个商用R134a、流程分配为12-8-8-6微通道冷凝器作为示例,用理论和实验方法分别得到了其管内冷凝平均传热系数和压降。结果表明,二者的偏差均落在30%以内。其中Koyama和Zhang提出的模型预测偏差较小,分别为-4.96%~11.31%,0.42%~25.14%。 The design method of the multi-pass parallel micro-channel condenser has great effect on the in-tube thermodynamic performance. However, there exist no simple and effective methods which can predict the in-tube heat transfer coefficient and pressure drop. A stepwise calculation method for the thermodynamic parameters of the multi tube pass parallel micro-channel condenser under varying mass flux and average vapor quality of each pass was proposed. Based on the assumption that the tube wall temperature is constant and the distribution of refrigerant in each tube-pass is uniform, the heat transfer models of Koyama and Wang, the pressure drop models of Zhang and Koyama were chosen to establish the correlation between tube wall temperature and heat flux, to iteratively calculate the in-tube heat transfer coefficient and pressure drop. This investigated micro-channel condenser has a flow path arrangement of 12-8-8-6, using R134a as working medium. The in-tube heat transfer coefficient and pressure drop were both theroretically and experimentally obtained. The results demonstrat that both heat transfer coefficient and pressure drop fall within 30%. The predicted errors by both Koyama model and Zhang model are smaller, ranging from-4.96% 11.31% and 0.42% 25.14%, respectively.
出处 《热科学与技术》 CAS CSCD 北大核心 2015年第6期476-483,共8页 Journal of Thermal Science and Technology
基金 国家自然科学基金资助项目(U0934006) 粤港关键领域重点突破资助项目(2009Z011) 广州市科技计划资助项目(7411804865260)
关键词 多管程 微通道冷凝器 平均传热系数 压降 multi-pass micro-channel condenser average heat transfer coefficient pressure drop
  • 相关文献

参考文献12

  • 1KILYOAN C, KWAN-SOO L, WOO-SEUNG K. Optimization of the design factors for thermal performance of a parallel-flow heat exchanger [J]. Heat and Mass Transfer, 2002, 45:4773-4780.
  • 2JIANG Y, GARIMELLA S. Compact air-coupled and hydronically coupled microchannel heat Pumps [C] // ASME International Mechanical Engineer- ing Congress and Exposition, New York, 2001= 227-239.
  • 3WEBB R L, LEE H. Brazed aluminum condensers or residential air conditioning [J]. Journal of Enhanced Heat Transfer, 2001, 8(1):1-13.
  • 4彭明,张雪平.不同流程布置的平流式冷凝器试验研究[J].制冷与空调(四川),2008,22(2):1-5. 被引量:16
  • 5张娅妮,陈蕴光,阚杰,孙民,袁秀玲.多元平行流冷凝器传热与流动性能模拟研究[J].哈尔滨工业大学学报,2008,40(3):483-487. 被引量:7
  • 6解文正,杜岭岭,高学攀,王振华.多元平行流冷凝器流程布置的模拟研究与分析[J].机械设计与制造,2011(3):89-91. 被引量:5
  • 7王荣汉,蔡亮,蔡华林,刘翀.扁管分配布置方式对平流式冷凝器换热性能影响[J].建筑热能通风空调,2010,29(2):37-40. 被引量:10
  • 8KOYAMA S, KUWAHARA K, NAKASHITA K, et al. An experimental study on condensation of refrigerant R134a in a multi-port extruded tube l-J]. International Journal of Refrigeration, 2003, 26 (4) :425-432.
  • 9WANG W W W, RADCLIFF T D, CHRISTENS- EN R N. A condensation heat transfer correlation for millimeter-scale tubing with flow regime transi- tion [J]. Experimental Thermal Fluid Science, 2002, 26(5) 473-485.
  • 10ZHANG M. A New Equivalent Reynolds Number Model for Vapor Shear-controlled Controlled Condensation Inside Smooth and Micro-fin Tubes [D]. PA:Pennsylvania State College, 1998.

二级参考文献18

  • 1舒朝晖,李丛来,陈焕新,金听祥,罗艳,符卫红,王福宝.扁管结构对平行流冷凝器制冷剂侧性能的影响[J].化工学报,2008,59(S2):129-133. 被引量:17
  • 2纪威.湿空气热物理性质计算方程及其修正系数[J].内蒙古工业大学学报(自然科学版),1994,13(3):22-28. 被引量:8
  • 3阚杰,郝亮,李涛,李强,袁秀玲,董晓俊.R404A和R410A应用于平行流冷凝器的模拟分析比较[J].制冷与空调,2007,7(1):56-60. 被引量:3
  • 4Lee G H,Yoo J Y.Performance analysis and simulation of automobile air conditioning system[J].International Journal of Refrigeration,2000,23 (3):243-254.
  • 5Saitoh S,Daiguji H,Hihara E.Effect of tube diameter on boiling heat transfer of R-134a in horizontal small-diameter tubes[J].International Journal of Heat and Mass Transfer,2005,48(23/24):4973-4984.
  • 6阙雄才,陈江平.汽车空调使用技术[M].北京:北京工业出版社,2003.
  • 7刘宪英.用热效率分析比较三种型式制冷机的经济性能.暖通空调,1985,15(4):12-15.
  • 8AHMET C,ERTAN B,DOGAN E.Exergoeconomie analysis of condenser type heat exehangers[J].Energy,2002,2(2):113-118.
  • 9JABARDO J M.Modeling and experimental evaluation of an automotive air conditioning system with a variable capacity compressor[J].International Journal of Refrigeration,2002,25(8):1157-1172.
  • 10LEE G H,YOO J Y.Performance analysis and simulation of automobile air conditioning system[J].International Journal of Refrigeration,2000,23(3):243-254.

共引文献28

同被引文献17

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部