期刊文献+

电力调度数据网业务往返路径不一故障分析 被引量:1

Analysis of Fault Analysis of Inconsistent Round Trip Path in the Power Dispatching Data Network
下载PDF
导出
摘要 为提高电力调度数据网业务保障水平,解决电力调度数据网业务往返路径不一的问题,文章通过研究电力调度数据网路由区分符(Route Distinguisher,RD)值的设置方法,并结合一起业务往返路径不一故障,通过故障情况和理论分析、实验测试等,深入查找故障原因,并提出了相应的解决方案,从而保证电力调度数据网的安全可靠运行。 In order to improve the service level of power dispatch data network, solve the problem of inconsistent round trip path in the power dispatching data network. This paper studies the configuration method of the RD(Route Distinguisher, RD) value of the power dispatching data network. Through malfunction analysis, theoretical analysis and experimental measurement, this paper finds out the cause of failure and proposes a corresponding solution to ensure the safe and reliable operation of power dispatching data network.
出处 《电力信息与通信技术》 2015年第12期91-93,共3页 Electric Power Information and Communication Technology
关键词 调度数据网 路由区分符 业务往返路径 power dispatching data network route distinguisher round trip of business