期刊文献+

唯一性检测在椭圆偏振光谱薄膜拟合中的应用(英文) 被引量:2

Uniqueness test for thin film fitting in spectroscopic ellipsometry
下载PDF
导出
摘要 利用椭圆偏振光谱进行薄膜样品的测量数据分析拟合时,薄膜厚度与介电常数通常具有一定的关联性.不同色散模型的选取也会对拟合结果产生明显的影响,引起较大误差.介绍了唯一性检测在椭偏拟合中的实现方法.并以二氧化钛样品为例,利用唯一性检测对比了不同色散模型、不同厚度、不同测量波段、不同入射角度时的唯一性检测结果.结果表明,唯一性检测能够有效标定出椭偏测量和拟合过程中所产生的误差,同时能够对不同色散模型进行量化对比,提升拟合精度. The thickness and dielectric constants of thin films usually have certain correlation in the fitting procedure of spectroscopic ellipsometry( SE). The choice of different dispersion models may also influence the results and cause errors. As the fitting is influenced by the dispersion models adopted in the analysis,the uniqueness test has been introduced into SE fitting. The results of uniqueness test have been compared with different dispersion models,different film thicknesses,different wavelength ranges and different incident angles using titanium dioxide samples as an example. It is indicated that uniqueness test is efficient in evaluating the fitting for SE measurement.Uniqueness test can also provide quantitative comparison among different dispersion models and contribute to fitting precision.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2015年第6期663-667,共5页 Journal of Infrared and Millimeter Waves
基金 Supported by National Natural Science Foundation of China(11174058,61275160,11374055,61427815) the No.2 National Science and Technology Major Project of China(2011ZX02109-004) the STCSM project of China(12XD1420600) Key Laboratory of infrared imaging materials and detectors,Shanghai Institute of Technical Physics,Chinese Academy of Sciences
关键词 椭圆偏振光谱 唯一性检测 薄膜 二氧化钛 spectroscopic ellipsometry uniqueness test thin film titanium dioxide
  • 相关文献

参考文献1

二级参考文献6

  • 1Imamura N, Ota C.Experimental study on magneto-optical disk exerciser with the laser diode and amorphous magnetic thin film [J]. Japan J. Appl. Phys., 1980,19:L731.
  • 2H W van Kesteren, Martynov Yu V, Penning F C, et al. Towards 100 Gb/in2 MO storage using a blue laser,high-NA far-field optics and domain-expansion media [J]. J. Magn. Soc. Jpn., 2001,25(3-2):334-338.
  • 3Bechevet B. New trends and technical challenges in optical storage [J]. Trans. Magn. Soc. Jpn., 2002,2:126-130.
  • 4Nakagawa K, Itoh A. Multi-valued MO recording and multi-wavelength readout [J]. J. Magn. Soc. Jpn., 1996,20(S1):73-78.
  • 5Itoh A, Nakagawa K, Shimazaki K, et al. High SNR readout method for double layered MO disk with single wavelengh LASER beam[J]. J. Magn. Soc. Jpn., 1999,23(S1):221.
  • 6Zak J, Moog E R, Liu C, et al. Universal approach to magneto-optics [J]. J. Magn. Magn. Mat., 1990,89:107-123.

同被引文献14

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部