期刊文献+

贯流式水轮机受油器外操作油管爆裂故障分析与处理 被引量:4

Analysis and Treatment of Crack Fault of External Operating Oil Pipe of Oil Supply Head in Tubular Turbine
下载PDF
导出
摘要 针对一起贯流式水轮机受油器外操作油管爆裂故障进行分析,并提出处理措施。通过现场检查与分析,确定受油器外操作油管焊接部位的焊缝薄弱和浮动瓦间隙不均匀是造成外操作油管爆裂的主要原因。采取了裂缝修补、焊缝补强、轴线调整以及受油座定位加固的处理措施。处理措施实施后,外操作油管补焊处及各联接管路与阀门均无渗漏油,机组恢复运行。 A crack fault of external operating oil pipe of oil supply head in tubular turbine is analyzed and treatment measures are proposed. By field inspection and analysis, main reasons of crack fault of external operating oil pipe are the weak weld at the weld position of external operating oil pipe of oil supply head and the non- uniform gap between floating tiles. Treatment measures were adopted including crack repair, weld reinforcement, axes adjustment and oil supply base positioning and reinforcement. After the adoption of measures, there are no leakage of oil at the repair welding position of external operating oil pipe, connecting pipes and valves, and the unit returned to operation.
作者 陈德忠
出处 《广西电力》 2015年第6期85-87,共3页 Guangxi Electric Power
关键词 贯流式水轮机 受油器 油管 轴线调整 tubular turbine oil supply head oil pipe axes adjustment
  • 相关文献

参考文献4

  • 1刘国选.灯泡贯流式水轮发电机组运行与检修[M].北京:中国水利水电出版社,1999.
  • 2沙锡林.贯流式水电站[M].北京:中国水利水电出版社,2006.
  • 3薄鑫涛,郭海祥,袁风送等.实用热处理手册[M].上海:上海科技出版社,2009.1:390,395.
  • 4GB/T8564-2003.水轮发电机组安装技术规范[S].2003.

共引文献56

同被引文献20

引证文献4

二级引证文献1

相关作者