期刊文献+

Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures

Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures
原文传递
导出
摘要 Purpose: Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success. However, these implants require precise placement under image intensifier guidance, which exposes the surgeon to substantial amount of radiation. It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available. Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier. Methods: Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and internal fixation with reversed contralateral distal femoral locking plate. The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score. Results: Twenty-one fractures united with the primary procedure, with a mean time of consolidation being 11 weeks (range, 9-16 weeks). One patient developed superficial suture line infection, which resolved with oral antibiotics. Another patient had a fall 3 weeks after surgery and broke the plate. Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united. Two cases had nonunion, which went in for union after bone grafting. The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97). Conclusion: The reversed contralateral distal femoral plate is a biomechanically sound implant, which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices. The added advantage of this implant is its usability in the absence of an image intensifier.
出处 《Chinese Journal of Traumatology》 CAS CSCD 2015年第5期279-283,共5页 中华创伤杂志(英文版)
关键词 Femoral fractures Bone plates Fracture fixation 下线 服务 迁移
  • 相关文献

参考文献20

  • 1Kyle RF, Cabanela ME, Russell TA, et al. Fractures of the proximal part of the femur, fnstr Course Lect. 1905;44:227-253.
  • 2Crist BD, Khalafi A, Hazelwood SJ, et al. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model. J Orthop Trauma. 2009,23: 622-627.
  • 3Latifi MH, Ganthel K, Rukmanikanthan S, et al. Prospects of implant with locking plate in fxation of subtrochanteric fracture: experimental demon- stration of its potential benefits on synthetic femur model with supportivehierarchical nonlinear hyperelastic finite element analysis. Biomed Eng Online, 2012,11:23.
  • 4Start AJ, Hay MT, Reinert CM, et al. Cephalomedullary nails in the treatment of high-energy proximal femur fractures in young patients: a prospective ran- domized comparison of trochanteric versus piriformis fossa entry portal. J Orthop Trauma. 2006;20:240-246.
  • 5Tencer AF, Johnson KD, Johnston DW, et al. A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur. J Orthop Res. 1984;2:297~305.
  • 6Neher C, Ostrum RF. Treatment of subtrochanteric femur fractures using a submuscular fixed low-angle plate. Am J Orthop. 2003;32:29-33.
  • 7Vaidya SV, Dholakia DB, Chatterjee A. The use of a dynamic condylar screw and biological reduction techniques for subtrochanteric femur fracture. Injury. 2003;34:123-128.
  • 8Boldin C, Seihert FJ, Fankhauser F, et al. The proximal femoral nail (PFN)--a minimal invasive treatment of unstable proximal femoral fractures: a pro- spective study of 55 patients with a follow-up of 15 months. Acta Orthop Scand. 2003;74:53-58.
  • 9van Meeteren MC, van Rief YE, Roukema JA. Condylar plate fixation of sub- trochanteric femoral fractures. Injury. 1996;27:715-717.
  • 10Ma CH, Tu YK, Yu SW, et al. Reverse LISS plates for unstable proximal femoral fractures. Injury. 2010;41:827-833.