期刊文献+

头带式连续血压检测装置设计

Design of A Headband Device with Continuous Blood Pressure Detection
下载PDF
导出
摘要 本文设计了一种基于脉搏波传导时间、能够对血压进行长时间连续测量的头带式装置。与传统信号采集方式不同,本装置信号的采集位置均在人体头部,通过嵌入在头带中的心电电极传感器和反射式脉搏波传感器分别采集心电信号(electrocardiogram、ECG)和光电容积脉搏波信号(photoplethysmography、PPG),并对二者进行特征点提取,测量心电信号的R波峰值和脉搏波信号最大值点之间的时间差得到脉搏波传导时间(pulse transit time、PTT)。基于动脉血压和脉搏波传导时间(PTT)之间的线性模型,利用脉搏波传导时间与水银血压计测得的收缩压和舒张压进行回归分析,得到收缩压和舒张压的计算公式。针对个体的实验结果分析表明,本装置与水银血压计测得数据误差在10mm Hg之内,能够满足AAMI国际标准对无创血压监测误差的要求。 In this paper, a headband device to realize the long time continuous detection of blood pressure was designed based on pulse wave transmission time(PTT). Different with the traditional signal acquisition method, the collection positions of the device were all located in the human head. The ECG signal and PPG signal were collected respectively by the electrode sensors and refl ex pulse wave sensor embedding in the belt at the same time, and then the characteristic points were extracted to obtain PPT by calculating the time gap between the peak of R-wave in ECG signal and the maximum point in PPG signal. We performed regression analysis by systolic blood pressure(SBP) and diastolicblood pressure(DBP) measured by PTT and a mercury sphygmomanometer based on the linear model between the arterial blood pressure and PTT and acquire the calculation formula. The experimental results indicated that the difference of SBP measured by the system and by the mercury sphygmomanometer was less than 10 mmHg, which could meet the AAMI requirement of noninvasive blood pressure measurement.
出处 《生命科学仪器》 2015年第6期36-39,20,共5页 Life Science Instruments
基金 国家自然科学基金(61471075) 重庆高校创新团队建设计划(智慧医疗系统与核心技术创新团队)
关键词 可穿戴装置 连续检测 脉搏波传导时间 血压 Wearable device Continuous detection Pulse wave transmission time Blood pressure
  • 相关文献

参考文献10

  • 1Luo C, Li T Y, Quan X L, et al. A new algorithm of blood pressure measurement based on oscillometric method[J]. Automation Congress, 2008: 1-4.
  • 2McGhee B. Monitoring arterial blood pressure: what you maynot knom[J]. Critical Care Nurse, 2002, 22(4) : 60-78.
  • 3焦学军,房兴业.连续每搏血压测量方法的研究进展[J].航天医学与医学工程,2000,13(2):148-151. 被引量:21
  • 4李章俊,王成,朱浩,金凡,马俊领.基于光电容积脉搏波描记法的无创连续血压测量[J].中国生物医学工程学报,2012,31(4):607-614. 被引量:53
  • 5Lass J, Meigas K, Karai D, et al. Continuous blood pressure monitoring during exercise using pulse wave transit time measurement[C]//Proceedingsofthe26th AnnuallnternationalConference of the IEEE EMBS.San Francisco: IEEE, 2004: 2239- 2242.
  • 6Lass J, Meigas K, Kattai R, et al. Optical and electricalmethods for pulse wave transit time measurement and itscorrelation with arterial blood pressure[J]. Proceedings oflhe Estonian Academy of Sciences, 2004, 10(4) : 123-136.
  • 7Shriram R, Wakankar A, Daimiwal N, et al. Continuouscuffless blood pressure monitoring based on PTT[C]//2010International Conference on Bioinformatics and BiomedicalTechnology. Chengdu, 2010: 51-55.
  • 8McCombie D, Shaltis P. Adaptive hydrostatic blood pressurecalibration: development of a wearable,autonomous pulsewave velocity blood pressure monitor[C]//Proeeedings ofthe 29th Annual International Conference of the IEEEEMBS. Lyon, 2007: 370-373.
  • 9Sahoo A, Manimegalai P, Thanushkodi K. Wavelet basedpulse rate and blood pressure estimation system from ECGand PPG signals[C]/Jlnternational Conference onComputer, Communication and Electrical Technology. Tamilnadu, 2011 : 285-289.
  • 10白丽红,王成,文苗,张通.基于脉搏波传导时间的连续血压监测系统[J].生物医学工程研究,2014,33(4):221-225. 被引量:19

二级参考文献50

共引文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部