说明了MIL-STD-461G草案的变化:在测试项上,去掉了电源线尖峰信号传导敏感度测试,增加了电缆束注入雷击感应的瞬态传导敏感度测试和人员携带静电放电测试;技术细节上,分析了标准在测试布置、测试设备、测试频率及测试方法上的改动。
Some significant updates of the MIL-STD-461 G draft is described by comparing against F edition. The CS106 conducted susceptibility,transients,power leadshas been removed,while CS117 conducted susceptibility,lightning induced transients,cables and power leads and CS118 personnel borne electrostatic discharge newly added. Then the technical changes of test setup,equipment,frequency range and test procedure are analyzed in detail.