摘要
多舱段载人航天器通常由主控舱段利用舱间通风对组合体空气环境参数进行集中控制.利用Ecosimpro建立了一种多舱段载人航天器CO2去除系统性能仿真分析模型,包括舱体模块、乘员模块、CO2净化模块、舱间通风模块,并对三舱段载人航天器CO2去除系统性能进行了计算分析.结果表明,当净化装置进风量为0.0072kg/s,非主控舱段驻留人数达到6人时,会造成非主控舱段CO2分压超出700 Pa的指标上限.此时增大舱间通风量对降低非主控舱段CO2分压的效果并不明显,有效的控制方式是增大净化装置进风量.当净化装置进风量增加至0.0113kg/s时,非主控舱段CO2分压可降至700Pa以下.该工作有助于加快载人航天器空气环境控制系统的设计和改进流程.
Air environment of human spacecraft with multi-cabin is usually controlled by one core cabin through inter-cabin ventilation. An integrated simulation model of CO2 removal system of human spacecraft with multi-cabin was developed with Ecosimpro,including cabin sub module,crew sub module,CO2 removal sub module,and inter-cabin ventilation sub module. Using this simulation model,the characteristics of CO2 removal system were analyzed. According to the results,when crew number in cabins without CO2 removal equipment is up to 6 and air flux into CO2 removal equipment is maintained at 0. 007 2 kg /s,CO2 partial pressure of cabins without CO2 removal equipment is beyond upper limit of 700 Pa. In that case,CO2 partial pressure could not be improved effectively by increasing inter-cabin ventilation flux. However,when air flux into CO2 removal equipment is increased from 0. 007 2 kg /s to 0. 011 3 kg /s,CO2 partial pressure of cabin without CO2 removal system is reduced below 700 Pa. The work is helpful to accelerate the process of design and improvement of air environment control system of human spacecraft.
出处
《北京航空航天大学学报》
EI
CAS
CSCD
北大核心
2014年第10期1349-1354,共6页
Journal of Beijing University of Aeronautics and Astronautics
基金
国家重大科技工程专项资助项目
关键词
载人航天器组合体
密封舱
空气环境
舱间通风
CO2去除
human spacecraft assemble
pressurized cabin
air environment
inter-cabin ventilation
CO2removal