期刊文献+

蓖麻油中无机元素的质谱分析

Analysis of Trace Inorganic Elements in Castor Oil by Inductively Coupled Plasma Mass Spectrometry
下载PDF
导出
摘要 建立了乙醇稀释-电感耦合等离子体质谱(ICP-MS)法测定蓖麻油中多个无机微量元素的分析方法。蓖麻油样品用乙醇稀释,使用ICP-MS法直接测定。在等离子体氩气流中加入少量氧气,使高浓度有机溶液进入等离子体中完全燃烧,防止了高碳在质谱锥口和离子透镜上的冷凝沉积,采用八极杆碰撞/反应池(ORS)消除了质谱干扰,多元素(Sc,Ge,Rh,Ir)内标溶液的使用消除了基体效应,维持了各元素分析信号的稳定,通过向待测溶液中加入Au标准溶液,使元素Hg形成金汞齐消除了记忆效应。20个待测元素的线性相关系数≥0.999 5,检出限在0.06-20.1ng·L^-1之间,回收率为90.4%-110.2%,相对标准偏差(RSD)≤4.8%。通过对不同来源蓖麻油样品进行分析,结果显示,三个样品中元素的含量存在较大差异。方法能快速、简便、准确测定蓖麻油中的多个无机元素。 A method for the determination of Na ,Mg ,Si ,P ,K ,Ca ,Cr ,Mn ,Fe ,Co ,Ni ,Cu ,Zn ,As ,Se ,Sr ,Mo ,Cd ,Hg and Pb in castor oil after direct dilution with ethanol by inductively coupled plasma mass spectrometry (ICP‐MS) was estab‐lished .The sample was diluted by ethanol before ICP‐MS determination .The condensation and deposition of high concentrations of carbon in mass cone interface and ion lens ,which will decrease the sensitivity of element analysis ,were avoided effectively by introducing O2 to plasma .The mass spectral interferences were eliminated by octopole reaction system (ORS) .The matrix effects were calibrated to using Sc ,Ge ,Rh and Ir as internal standard elements .Au standard solution ,which could form amal‐gam alloy with Hg ,was dropped to eliminate the memory effect of Hg .The results show that the correlation coefficient for ana‐lyte is no less than 0.999 5 ,the detection limits is in the range of 0.06-20.1 ng·L^-1 ,the recovery is in the range of 990.4%-110.2% ,and the RSD is less than 4.8% .This method was very fast ,simple and accurate to simultaneously analyze multi‐ele‐ments in castor oil .
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2015年第10期2882-2885,共4页 Spectroscopy and Spectral Analysis
基金 国家自然科学基金项目(21075138) 湖南省高校产业化培育项目(13CY019) 湖南省教育厅重点科研项目(14A035) 湖南省自然科学基金项目(14JJ5032) 湖南省重点学科建设项目资助
关键词 蓖麻油 电感耦合等离子体质谱 元素 乙醇 Castor oil Inductively coupled plasma mass spectrometry Elements Ethanol
  • 相关文献

参考文献12

  • 1de Souza R M, Leocadio L G, da Silveira C L P. Analytical Letter, 2008, 41(9) : 1615.
  • 2WANGLin—lin,I.INLi,CHENYu-hong(t琳琳,林立,陈玉红).环境化学,2011,32(2):571.
  • 3de Jesus A, Silva M M, Vale M G R. Talanta, 2008, 74(5) : 1378.
  • 4de Souza J R, dos Santos E F, Duyck C B, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2011, 66(5) : 356.
  • 5Ghisi M, Chaves E S, Quadros D P C, et al. Microchemieal Journal, 2011, 98(1): 62.
  • 6Quadros D P C, Rau M, Idrees M, et al. Spectrochimica Acta Part 13: Atomic Spectroscopy, 2011, 66(5) : 373.
  • 7Pereira J S F, Picoloto R S, Pereira L S F, et al. Analytical Chemistry, 2013, 85(22) : 11034.
  • 8Mulle A L H, Muller C C, Lyra F, et al. Food Analytical Methods, 2013, 6(1) : 258.
  • 9朱乾华.电感耦合等离子体质谱法测定锰酸锂中杂质元素[J].光谱学与光谱分析,2013,33(5):1350-1353. 被引量:7
  • 10Bakircioglu D, Kurtulus Y B, Yurtsever S. Journal of Analytical Atomic Spectrometry, 2012, 27(9): 1456.

二级参考文献9

  • 1Lante A, Lomolino G, Cagnin M, et al. Food Control, 2006, 17(3): 229.
  • 2Suleiman J S, Hu B, Peng H, et al. Talanta, 2009, 77(5): 1579.
  • 3Ruiz S G, Moldovan M, Fortunato G, et al. Anal. Chim. Acta, 2007, 590(1): 55.
  • 4Elwaer N, Hintelmann H. Talanta, 2008, 75(1): 205.
  • 5Pick D, Leiterer M, Einax J W. Microchem. J. , 2010, 95(2): 315.
  • 6Guillong M, Danyushevsky L, Walle M, et al. J. Anal. At. Spectrom. , 2011, 26(7): 1401.
  • 7Infante H G, Sturgeon R, Turner J, et at. Anal. Bioanal. Chem., 2008, 390(2): 629.
  • 8张莉莉,汝坤林.锂离子电池正极材料LiMn2O4中杂质Fe的测定[J].电池,2008,38(2):130-131. 被引量:4
  • 9张莉莉,穆远庆.FAAS测定锂离子电池正极材料LiMn_2O_4中的杂质钠[J].光谱实验室,2008,25(6):1108-1111. 被引量:4

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部