油浸式电力变压器绝缘状况的回复电压法研究 被引量:5

Study on the method of voltage recovery insulation condition of oil immersed power transformer
原文传递
导出
摘要 油浸式电力变压器是电力系统中重要的电气设备,其运行状况的好坏会直接影响到大电网的安全运行,对其绝缘状况进行研究具有重要意义。搭建油纸绝缘系统扩展的Debye仿真模型,得出充电电压、充放电时间比和绝缘电阻等参数的变化对回复电压参数的影响关系图;对不同糠醛含量值进行测试,得出其对回复电压各参数的对应关系。糠醛实验研究和回复电压参数的仿真分析的结合,对比回复电压法参数的变化情况,进一步验证回复电压方法的可靠性,为今后对变压器的整体绝缘状态的诊断提供依据。 The oil immersed power transformer is a important equipment in power system,its running state can directly affects the reliable operation of large power grid,conducts the research to the insulation condition has important significance.Through the expansion Debye simulation model in oil paper insulation system was built,the diagram between the charging voltage.the ratio time of charging to discharging,insulation resistance and the recovery voltage parameters were got.By testing on the different content value of furfural,can get the relation to the recovery voltage method.The combination of the study to furfural and the analysis to the recovery voltage parameters,compare with the change of recovery voltage parameters,can further text the reliability of the recovery voltage method,provide the basis for the diagnosis of transformer insulation condition in the future.
出处 《自动化与仪器仪表》 2015年第5期16-19,共4页 Automation & Instrumentation
关键词 回复电压 绝缘 变压器 糠醛 The return voltage Insulation Transformer Furfural
  • 相关文献

参考文献6

二级参考文献57

  • 1宋伟,A.J.Kachler.变压器老化评估的极化去极化电流分析法[J].变压器,2005,42(7):28-34. 被引量:25
  • 2董明,张瑞刚,张冠军,严璋.回复电压法在变压器故障诊断中的应用[J].电网与水力发电进展,2007,23(3):21-25. 被引量:18
  • 3许维宗,刘勇,许文蕾,江霞.电力变压器油纸绝缘状态的诊断——回复电压法[J].华中电力,2007,20(4):4-7. 被引量:14
  • 4Jaroslaw Gielniak, Marek Ossowski. Dielectric response of oil paper insulation systems of large moisture and temperature in homogeneity[C]//Proceedings of the XIVth International Symposium on High Voltage Engineering. Beijing, China: Tsinghua University, 2005: 25-29.
  • 5Leibfried T, Kachler A J, Zaengl W S, et al. Ageing and mois ture analysis of power transformer insulation systems[C]// Proceedings of 2002 CIGRE Session. Paris, France: CIGRE, 2002: 12-101.
  • 6Debangshu Dey, Biswendu Chatterjee, Sivaii Chakravorti, et al. Importance of denoising in dielectric response measurements of transformer insulation: an uncertainty analysis based approach [J]. Measurement, 2010, 43(1) : 54-66.
  • 7ZHANG Tao, CAI Jin-ding. Study on voltage response method of transformer condition assessment [C]// 2008 International Conference on High Voltage Engineering and Application. Chongqing, China: [s. n.], 2008: 580-583.
  • 8Saha T K, Yao Z T, Le T T, et al. Investigation of interracial polarization spectra parameters for accelerated aged oil-paper insulation and its correlation with molecular weights and furan compounds[C]// Proceedings of 2000 CIGRE Session. Paris, France: CIGRE, 2000:15-201.
  • 9Saha T K, Yao Z T. Experience with return voltage measurements for assessing insulation conditions in service aged transformers[J]. IEEE Transactions on Power Delivery, 2003, 18 (1), 128-135.
  • 10Saha T K, Purkait P. Understanding the impacts of moisture and thermal ageing on transformer's insulation by dielectric response and molecular weight measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15 (2): 568-582.

共引文献116

同被引文献48

引证文献5

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部