摘要
通过对酒钢3×21000 m^3/h制氧空压机轴位移检测系统故障停机的问题分析,着重阐述了轴位移检测装置的故障分析和解决方法。
Through analyzing the shutdown accident of Jiuquan Steel's 3 ×21000 m^3/h oxygen generation compressor caused by failure of the axial displacement detecting system,analysis and solution of the fault in the axial displacement detecting system are mainly presented.
出处
《冶金动力》
2016年第1期24-26,29,共4页
Metallurgical Power
关键词
轴位移
传感器
前置器
故障
安装调试
axial displacement
sensor
proximitor
malfunction