期刊文献+

直肠磁共振弥散峰度成像可重复性评价 被引量:4

The Reproducibility of Diffusional Kurtosis Imaging for Rectum in Vivo
下载PDF
导出
摘要 目的:探讨Philips Achieva 3.0T TX磁共振直肠弥散峰度成像的可重复性。方法:应用Philips Achieva 3.0T TX超导型磁共振扫描仪。8通道体部相控阵线圈。对27例健康志愿者在不同时间(24小时~2周内)行两次行DKI扫描。DKI采用单次激发自旋回波-平面回波(SE-EPI)序列,启用5个扩散梯度场(b=0、500、1000、1500、2000 s/mm2),扩散梯度同时取X、Y和Z三个方向。由两名5年以上工作经验的医生双盲对图像进行后处理,获得同一层面的MD值、MK值,然后进行统计学分析。结果:所有27例志愿者均成功获得DKI数据。MD值及MK值观察者内相关系数分别为0.962、0.958;变异系数分别为17.8%、18.9%。MD值及MK值观察者间相关系数分别为0.925、0.895;变异系数分别为18.5%、23.6%。结论:直肠弥散峰度成像具有较高的可重复性。 Purpose: To assess the reproducibility of diffusion kurtosis imaging(DKI) for rectum. Methods: This study was approved by our institutional review board and with informed consent. Twenty-seven healthy volunteers underwent 3-T magnetic resonance imaging twice with an interval of 24 hours to 14 days by using axial fat suppressed single-shot echo-planar DK imaging (five b-values) and torso phased-array coil. Parameters maps were obtained for the metric K, a measure of excess kurtosis of diffusion, and corrected diffusion (D), a corrected diffusion coefficient accounting for the non-Gaussian behavior. The inter- and intra-observer consistency was evaluated by using reliability test in SPSS 11.5. Results: Paired t-tests demonstrated that there was no significant difference between inter- and intra-observer (all P〉0.05). Intra-class correlation coefficients of the inter- and intra-observer were 0.962 (D), 0.958 (K) and 0.925 (D), 0.895 (K) respectively. Coefficients of variation were 17.8% (D), 18.9% (K) and 18.5% (D), 23.6% (K). Conclusion: DKI showed good reproducibility between paired observers and paired scans. The parameters D and K would be the foundation for further experiments and clinical application of DK imaging.
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2015年第6期524-527,共4页 Chinese Computed Medical Imaging
基金 福建省卫生计生委青年科研课题NO.2015-1-13~~
关键词 DKI 直肠 结果可重复性 水成像 Diffusional kurtosis imaging Rectum Reproducibility of results Water diffusion
  • 相关文献

参考文献17

  • 1Yablonskiy DA, Bretthorst GL, Ackerman JJ. Statistical model for diffusion attenuated MR signal. Magn Reson Med, 2003, 50: 664- 669.
  • 2Jensen JH, Helpern JA. Quantifyingn non-Gaussian water diffusion by means of pulsed-field-gradient MRI. Proceedings of the l lth Annual Meeting of Lsmrm, Toronto, Canada, 2003.
  • 3Jensen JH, Helpern JA, Ramani A, et al. Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging. Magn Reson Med, 2005, 53: 1432- 1440.
  • 4Lu H, Jensen JH, Ramani A. Three-dimensional characterization of non-gaussian water diffusion in humans using diffusion kurtosis imaging. NMR Biomed, 2006, 19: 236-247.
  • 5Hui ES, Cheung MM, Qi L, et al. Towards better MR characterization of neural tissues using directional diffusion kurtosis analysis. Neuroimage, 2008, 42: 122-134.
  • 6Helpern JA, Adisetiyo V, Falangola MF, et al. Preliminary evidence of altered gray and white matter microstructual development in the frontal lobe of adolescents with attention-deficit hyperactivity disorder: a diffusional kurtosis imaging study. J Magn Reson Imaging, 2011, 33: 17-23.
  • 7Jensen JH, Falangola MF, Hu C, et al. Preliminary observations of increased diffusional kurtosis in human brain following recent cerebral infarction. NMR Biomed, 2011, 24: 452-457.
  • 8Wang JJ, Lin W, Lu CS, et al. Parkinson disease: diagnostic utility of diffusion kurtosis imaging. Radiology, 2011, 261 : 210-217.
  • 9Ramani A, Jensen JH, Szulc KU, et al. Assessment of abnormalities in the cerebral microstructure of schizophrenia patients: a diffusional kurtosis imaging study[C]//Proceedings of the 15th Annual Meeting oflSMRM, Berlin, Germany. 2007: 648.
  • 10Raab P, Hattingen E, Franz K, et al. Cerebral gliomas: diffusional kurtosis imaging analysis of microstructural differences. Radiology, 2010, 254: 876-881.

同被引文献32

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部