期刊文献+

3D UTE定量评估骨皮质结合水和自由水的实验研究

The Experimental Study of Quantitative Assessment of Bound and Free Water in Bovine Cortical Bone Using 3D UTE Sequence
下载PDF
导出
摘要 目的:本研究尝试采用3D UTE成像及双指数T2*衰减模型分离骨皮质结合水和自由水。方法:在3T Skyra下对6例成年牛胫骨中段标本进行3D UTE成像,构建UTE双指数T2*衰减模型,对6例牛骨样本不同回波时间的UTE图像进行拟合,分别得到双指数拟合结果。结果:6例样本双指数拟合后,结合水(短)T2*=0.30ms,占比约81.6%,自由水(长)T2*=2.74ms,占比约18.4%。结论:3D UTE双指数衰减模型是一个有效的分离骨皮质结合水和自由水的方法,为定量评估骨质量提供了新的生物学指标,其对骨皮质结合水和自由水的分离有助于骨的力学性质的推断。 Purpose: This study attempted to use 3D UTE imaging with dual exponential T2* attenuation model for separating bound and free water in cortical bone. Methods: Six cases of adult bovine tibia were undergone 3D UTE imaging at 3T Skyra scanner, the dual exponential T2* relaxation model was constructed. UTE images of 6 bovine bone samples with different echo time were fitted in Matlab,and the fitted apparent bound and free water in cortical bone were obtained. Results: The average T2* values of bound and free water in bovine cortical bone fitted by the dual exponential fitting was 0.30 ms and 2.74 ms, accounted for approximately 81.6% and 18.4% in volume, respectively. Conclusion: 3D UTE with dual exponential decay model is an effective fitting method to separate the bound and free water in cortical bone, and provides a new biological indicator for quantitative bone quality, which can be potentially helpful to assess the mechanical properties of cortical bone.
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2015年第6期591-595,共5页 Chinese Computed Medical Imaging
基金 上海市科委西医类引导项目(14411962700) 江苏省自然科学基金面上项目(BK20151293)~~
关键词 3D ultra-short ECHO time imaging 骨皮质 结合水 自由水 双指数拟合 3D ultra-short echo time imaging Cortical bone Bound water Free water Dual exponential fitting
  • 相关文献

参考文献15

  • 1Ong HH, Wright AC, Wehrli FW. Deuterium nuclear magnetic resonance unambiguously quantifies pore and collagen-bound water in cortical bone. J Bone Miner Res, 2012, 27: 2573-2581.
  • 2Du J, Carl M, Bydder M, et al. Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone. J Magn Reson, 2010, 207: 304-311.
  • 3Cummings SR, Karpf DB, Harris F, et al. Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs. Am J Med, 2002, 112: 281- 289.
  • 4Schuit SC, van der Klift M, Weel AE, et al. Fracture incidence and association with bone mineral density in elderly men and women: the Rotterdam Study. Bone, 2004, 34: 195-202.
  • 5Nyman JS, Ni Q, Nicolella DP, et al. Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone. Bone, 2008, 42:193-199.
  • 6Horch RA, Gochberg DF, Nyman JS, et al. Non-invasive predictors of human cortical bone mechanical properties: T(2)- discriminated H NMR compared with high resolution X-ray. PloS One, 2011, 6: e16359.
  • 7Horeh RA, Nyman JS, Gochberg DF, et al. Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging. Magn Resort Med, 2010, 64: 680-687.
  • 8Ni QW, Nyman JS, Wang XD, et al. Assessment of water distribution changes in human cortical bone by nuclear magnetic resonance. Meas Sci Technol, 2007, 18: 715-723.
  • 9包尚联,杜江,高嵩.核磁共振骨皮质成像关键技术研究进展[J].物理学报,2013,62(8):513-519. 被引量:14
  • 10马立恒,孟悛非,陈应明,孙海兴,张朝晖.影响短T2成分MR三维超短回波时间双回波脉冲序列成像质量因素的探讨[J].中华放射学杂志,2011,45(4):388-391. 被引量:4

二级参考文献50

  • 1Robson MD,Gatehouse PD,Bydder GM,et al.Human imaging of phosphorus in cortical and trabecular bone in vivo.Magn Reson Med,2004,51:888-892.
  • 2Benjamin M,Bydder GM.Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences.J Magn Reson Imaging,2007,25:381 -389.
  • 3Reichert IL,Robson MD,Peter D,et al.Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.J Magn Reson Imaging,2005,23:611-618.
  • 4Henkelnan RM,Stanisz GJ,Graham SJ.Magnetization transfer in MRI:a review.NMR Biomed,2001,14:57-64.
  • 5Robson MD,Gatehouse PD,Bydder GM,et al.Magnetic resonance:an introduction to ultrashort TE (UTE) imaging.J Comput Assis Tomogr,2003,27:825-846.
  • 6Fenrich FR,Beaulieu C,Allen PS.Relaxation times and microstructures.NMR Biomed,2001,4:133-139.
  • 7Robson MD,Bydder GM.Clinical ultrashort echo time imaging of bone and other connective tissues.NMR Biomed,2006,19:765 -780.
  • 8Holmes JE,Bydder GM.MR imaging with ultrashort TE (UTE) pulse sequences:basic principles.Radiography,2005,11:163-174.
  • 9Reiehert IL,Benjamin M,Gatehouse PD,et al.Magnetic resonance imaging of periosteum with Ultrashort TE pulse sequences.J Magn Reson Imaging,2004,19:99-107.
  • 10包尚联, 周传农, 郭占国 2010 医学影像生物学基础(第1版) (北京:高等教育出版社)第99页].