期刊文献+

影响双源CT冠脉造影评估冠脉狭窄程度的因素分析 被引量:3

Influence Factors of Dual-source CT Coronary Angiography in Evaluating the Degree of Coronary Stenosis
下载PDF
导出
摘要 双源CT已成为临床诊断冠心病的一线检查手段,但与侵入性冠脉造影(Invasive Coronary Angiography,ICA)相比,其诊断冠脉狭窄程度的敏感性和特异性仍有较大程度的波动。以侵入性冠脉造影为金标准,本文对常见的影响双源CT冠脉造影评估冠脉狭窄程度的因素作一综述。 Since the advent of dual-source CT in 2005, dual-source CT coronary angiography (DSCT-CA)has been the first line examination method for the coronary artery disease (CAD), with its high temporal resolution, spatial resolution and the characteristics of the noninvasive examination.But compared with the invasive coronary angiography, the sensitivity and specificity of dual-source CT coronary angiography in the diagnosis of coronary artery stenosis degree is still with a larger degree of volatility.With invasive coronary angiography as the gold standard, this review presents the common factors which influence the evaluation of the degree of coronary stenosis by dual-source CT coronary angiography.
作者 庄玲玲 张皓
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2015年第6期601-604,共4页 Chinese Computed Medical Imaging
关键词 冠状动脉造影 双源CT 冠脉狭窄 Coronary angiography DSCT Coronary stenosis
  • 相关文献

参考文献26

  • 1Li M, Zhang JM, Zhao JS, et al. Diagnostic performance of dual- source CT coronary angiography with and without heart rate control: systematic review and meta-analysis. Clin Radiol, 2014, 69: 163-171.
  • 2徐怡,唐立钧,朱晓梅,徐海,祝因苏.双源CT冠脉成像评估冠脉狭窄不准确的原因分析[J].中国医学计算机成像杂志,2013,19(2):127-131. 被引量:18
  • 3Chen HW, Fang XM, Hu XY, et al. Efficacy of dual-source CT coronary angiography in evaluating coronary stenosis: initial experience. Clin Imaging, 2010, 34: 165-171.
  • 4刘成磊,杨立民,徐凯.双源CT诊断冠脉狭窄的价值—与冠状动脉造影对照分析[J].医学影像学杂志,2010,20(5):663-666. 被引量:10
  • 5Li C J, Hsu JC, Lai YJ, et al. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification. Clin Radiol, 2010, 65: 109-117.
  • 6Tsiflikas I, Brodoefel H, Reimann A J, et al. Coronary CT angiography with dual source computed tomography in 170 patients. Eur J Radiol, 2010, 74: 161-165.
  • 7高敏,肖践明,胡钊,郭涛.双源CT冠脉成像与冠脉造影对冠心病诊断价值的分析[J].昆明医学院学报,2009,30(3):94-97. 被引量:18
  • 8Hu XH, Zheng WL, Wang D, et al. Accuracy of high-pitch prospectively ECG-triggering CT coronary angiography for assessment of stenosis in 103 patients: comparison with invasive coronary angiography. Clin Radiol, 2012, 67: 1083-1088.
  • 9Salavati A, Radmanesh F, Heidari K, et al. Dual-source computed tomography angiography for diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. J Cardiovasc Comput Tomogr, 2012, 6: 78-90.
  • 10Meng L, Cui L, Cheng Y, et al. Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol, 2009, 10: 347-354.

二级参考文献51

  • 1陈家荣,唐立钧.双源CT冠状动脉血管成像技术及临床应用[J].实用医技杂志,2008,15(13):1661-1663. 被引量:2
  • 2王怡宁,金征宇,孔令燕,宋兰,张竹花,张抒扬,林松柏,牟文斌,王沄,赵文敏,郭家武.64层螺旋CT冠状动脉成像初步研究[J].中华放射学杂志,2006,40(8):797-801. 被引量:99
  • 3蒋瑾,付凯.双源CT的临床应用[J].实用医院临床杂志,2006,3(5):89-90. 被引量:38
  • 4BECK T,BURGSTAHLER C,REIMANN A,et al. Technology insight:possible applications of multislice computed tomography in clinical cardiology[ J ]. Natl Clin Pract Cardiovasc Med, 2005,2(7 ) : 61 - 368.
  • 5HABERL R,TITFUS J, BOHME E,et al. Multislice spiral computed tomographec angiography of coronary arteries in patients with suspected coronary artery disesse: an effective filter before catheter angiography [ J ] . Am Heart J,2005,149:1112 - 1129.
  • 6SCHEFFEL H,ALKADHI H,PLASS A,et al. Accuracy of dual source CT coronary angiography:first experience in high pretest probability population without heart rate control[ J ]. Eur Radiol, 2006, 16 ( 12 ) : 2739 - 2747.
  • 7Flohr TG,McCollough CH,Bruder H,et al.First Performance Evaluation of a Dual-source CT (DSCT)System[J].Eur Radiol,2006,16(2):256-268.
  • 8Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease.Report of the adhoc committee for grading of coronary Artery disease,council on cardiovascular surgery,American Heart Association[J].Circulation,1975,51:5.
  • 9Nieman K,Oudkerk M,Rensing,et al.Coronary angiography with multi-slice computed tomography[J].Lancet,2001,357:599-603.
  • 10Thomas G,Cynthia H,Herbert B,et al.First performance evaluation of a dual-source CT(DSCT) system[J].Eur Radiol,2006,16:256.

共引文献56