白马湖备用水源取水泵站设计要点 被引量:2

Design Essentials of Baima Lake Reserve Water Intake Pumping Station
原文传递
导出
摘要 白马湖备用水源取水泵站总规模为15×104m3/d,水源取自滨江区自然湖泊——白马湖,泵房建于白马湖西侧,对备用水源选择、取水泵站位置选择、配泵方案比选、输水线路方案比选、构筑物形式、取水方式等方案进行了论证,确定了可靠的工程方案,项目的实施增强了区域应急供水安全性并保证了钱塘江主水源咸潮期间避咸蓄淡的运行要求。 The total capacity of Baima Lake reserve water intake pumping station is 15 × 104 m3/ d. Water is taken from an natural lake in Binjiang, Baima Lake, and the pumping station is located at the west side of the lake. The reserve water source location, pumping station location, pump program selec- tion, water diversion route selection, structure form, water intaking mode were demonstrated. A reliable project scheme was determined, the project enhances emergency water supply security, and it is helpful for avoiding saltwater and storing freshwater during the salt tide of the Qiantang River.
出处 《中国给水排水》 CAS CSCD 北大核心 2016年第2期38-40,共3页 China Water & Wastewater
关键词 白马湖 取水泵站设计 泵房位置 输水线路 构筑物形式 取水方式 Baima Lake design of water intake pumping station pumping station location water diversion route structure form water intake mode