期刊文献+

血液传染性指标检测方法的随机质控设计与应用 被引量:1

The design and application of randomized quality control in blood transfusion disease testing
下载PDF
导出
摘要 目的通过对ELISA检测项目进行质控方案设计,建立完全随机方式的质控加样方法。方法设计基于时间序列的的数学模型,通过对时间中分钟和秒钟的末位进行计算,使质控品随着加样时间的变化,产生不同的位置结果,并依此进行加样。结果质控品在ELISA加样过程中会在板的任意位置进行加样,实现随机出现。结论本实验所使用的方法可以实现酶免检测质控的完全随机化。 Objective Through the design of a quality control inspection for ELISA tests, a completely random quality control method was built. Methods We built a mathematical model based on time series—the samples are calculated with changes in minutes and seconds time in a given time. This calculation helped to make changes on positions with time during the quality control sampling process. Results The sampling positions will be randomized on the plate during the process of ELISA quality control. Conclusion The method used in this experiment helped to build a complete randomized quality control of enzyme immunoassay.
作者 张立波 庞蓉蓉 王勇 黄敏 何成涛 傅强 曲贤敏 仲昭衍 ZHANG Libo;PANG Rongrong;WANG Yong;HUANG Min;HE Chengtao;FU Qiang;QU Xianmin;ZHONG Zhaoyan(Nanjing Red Cross Blood Center,Nanjing 210003,China;Ausbio Biotech Ltd)
出处 《中国输血杂志》 CAS 2018年第12期1348-1350,共3页 Chinese Journal of Blood Transfusion
基金 江苏省采供血行业科研专项资助项目(JS2018034)
关键词 采供血机构 随机质控 ELISA 时间 blood banks random quality inspection ELISA time
  • 相关文献

参考文献4

二级参考文献18

  • 1曹庆宏,刘素珍,朱广亮.孵育设备对ELISA检测试验的影响[J].中国输血杂志,2005,18(2):128-129. 被引量:6
  • 2徐树良,孙启俊,谈维,杜义真.分窗数字显时自动酶免孵育仪的应用[J].中国输血杂志,2005,18(6):488-489. 被引量:1
  • 3GB/T 19000-2008 质量管理体系基础和术语.
  • 4普通高中课程标准实验教科书.《数学3》(必修A版).北京:人民教育出版社,2004
  • 5高惠璇编著.统汁汁算.北京:北京大学出版社,1996
  • 6GB/T20468-2006.临床实验室定量测定室内质量控制指南.
  • 7CNAS-CL02医学实验室质量和能力认可准则.ISO15189:2007.
  • 8中国合格评定国家认可委员会.CNAS-CL39医学实验室质量和能力认可准则在临床免疫学检验领域的应用说明.2013-04-01.
  • 9中国合格评定国家认可委员会.CNAS-CL38医学实验室质量和能力认可准则在临床化学检验领域的应用说明.2013-04-01.
  • 10中国合格评定国家认可委员会.CNAS-RL02能力验证规则.2011-02-01.

共引文献112

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部