摘要 低低温电除尘技术二次扬尘增加,必须采取相应措施才能发挥其高除尘效率。分析了低低温电除尘器二次扬尘的特点和国外采取的措施及研究现状,包括离线振打、旋转电极技术两种解决方法。提出了新型解决低低温电除尘器二次扬尘的方法,即优化振打系统,并将该技术在长兴电厂低低温电除尘器中的应用作了重点阐述,成功解决了该项目的二次扬尘问题。 Dust re-entrainment is an important problem in low-low temperature electrostatic precipitator( LLT-ESP) technology and measures should be taken to get the high collection efficiency of PM. By analyzing the characteristics and research situation at abroad of LLT-ESP,two solving measures of dust re-entrainment were used including moving electrode type electrostatic precipitator( MEEP) and optimized rapping method. The paper provided a new measure named optimized rapping method to solve the dust re-entrainment in LLT-ESP,then emphasized the optimized rapping method and solved the dust reentrainment on Changxing LLT-ESP item.
出处 《环境工程》 CAS CSCD 北大核心 2016年第1期65-68,共4页 Environmental Engineering
基金 国家863计划项目(2013AA065002) 省重大科技专项计划项目(2013C01054)
关键词 低低温电除尘技术 二次扬尘 优化振打制度 旋转电极 LLT-ESP dust re-entrainment optimized rapping method MEEP
  • 相关文献

参考文献9

  • 1赵海宝,郦建国,何毓忠,姚宇平.低低温电除尘关键技术研究与应用[J].中国电力,2014,47(10):117-121. 被引量:113
  • 2郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第15届中国电除尘学术会议论文集.安徽,2013.
  • 3Yoshio Nakayama,Satoshi Nakamura,Yasuhiro Takeuchi,et al.MHI High Efficiency System-Proven Technology for Multi Pollutant Removal[R].Hiroshima Research&Development Center,2011:1-11.
  • 4Masami Kato,Tadashi Tanaka,Yasuki Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA,5282429[P].1994-02-1.
  • 5Sugita Y.Development and Demonstration of Waste Heat Integration with Solvent Process for More Efficient CO2Removal from Coal-Fired Flue Gas[C].Project Review Meeting.Southern Company,2012.
  • 6Mori Yusuke,Tsumita Yoshimitsu,Matsumoto Ario,et al.Operation results of IHI flue gas desulfurization system-unit No.1(1000MW)of Hitachinaka Thermal Power Station for TEPCO[J].IHI Engineering Review,2006,39(1):22-26.
  • 7Toshiaki Misaka,Yoshihiko,Mochizuki.Recent application and running cost of moving electrode type electrostatic precipitator[C]∥11th International Conference on Electrostatic Precipitation,2008:518-522.
  • 8名嶋慎司.石炭火力用低低温電気集塵装置[J].住友重機械技報,2001,146(10):35-38.
  • 9Stephen L Francis,Andreas Bck,Per Johansson.Reduction of Rapping Losses to Improve ESP Performance[C]∥11th International Conference on Electrostatic Precipitation,2008:45-49.

二级参考文献13

  • 1郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第十五届中国电除尘学术会议论文集.2013.
  • 2YOSHIO Nakayama,SATOSHI Nakamura,YASUHIRO Takeuchi,et al.MHI high efficiency system-proven technology for mul.
  • 3MASAMI Kato,TADASHI Tanaka,YASUKI Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA.
  • 4土屋喜重,川西好光,大西召一,等.Very cold electrostatic technology of advanced flue gas treatment system for co.
  • 5柳生隆志,土屋喜重,大西召一,等.Recent electrostatic precipitation technology[J].三菱重工技报,1996,33(1):69-73.
  • 6Development and demonstration of waste heat integration with solvent process for more efficient CO2 removal f.
  • 7柴田宪司,三重野光博,山本卓也.電気集麈方法[P].三菱重工技报.2000.
  • 8TOSHIAKI Misaka,YOSHIHIKO Mochizuki.Recent application and running cost of moving electrode type electrostati.
  • 9STEPHENL Francis,ANDREAS Back,PER Johansson.Reduction of rapping losses to improve ESP performance[C]//11th I.