期刊文献+

双磁透镜对时间展宽分幅变像管性能的影响 被引量:16

Influence of Double Magnetic Lenses on Performance of Pulse-Dilation Framing Tube
原文传递
导出
摘要 采用双磁透镜设计时间展宽分幅变像管,对其空间分辨特性进行模拟和测试。采用2#分辨率板测试像管空间分辨率,以及大面积阴极测试像管在离轴位置的空间分辨能力。测试结果表明,双磁透镜像管的空间分辨率为74 mm;在图像缩小1倍时,能有效分辨阴极距离中心轴位置30 mm的信息。像管的空间分辨率和在阴极离轴位置的分辨能力都优于单磁透镜像管。因此,双磁透镜能有效提高时间展宽分幅变像管的空间分辨特性。 The pulse-dilation framing tube using the double magnetic lenses is designed and the performance of spatial resolution is simulated and measured. The spatial resolution of tube is measured through the 2# plate. The spatial resolution at the off-axis position is tested through a large cathode. The measurement results show that the spatial resolution of tube is 74 μm, and the 30 mm off-axis position on the cathode is resolved while the image is demagnified 1 times. The spatial resolution and the spatial resolving power at the off-axis position are better than the tube using the single magnetic lens. Therefore, the spatial resolving performance of pulse-dilation framing tube is improved by the double magnetic lenses.
出处 《激光与光电子学进展》 CSCD 北大核心 2016年第1期248-252,共5页 Laser & Optoelectronics Progress
基金 国家自然科学基金(11305107) 广西教育厅科研项目(LX2014125)
关键词 超快光学 分幅变像管 时间展宽技术 微通道板 空间分辨率 超快现象 磁透镜 ultrafast optics framing tube pulse dilation technology micro-channel plate spatial resolution ultrafast phenomena magnetic lens
  • 相关文献

参考文献20

  • 1S H Glenzer, B J MacGowan, P Michel, et al.. Symmetric inertial confinement fusion implosions at ultra-high laser energies[J]. Science, 2010, 327(5970): 1228-1231.
  • 2Shaoen Jiang, Longfei Jing, Yunbao Huang, et al.. Novel free-form hohlraum shape design and optimization for laser- driven inertial confinement fusion[J]. Physics of Plasmas, 2014, 21(10): 102710.
  • 3A N Simakov, D C Wilson, S A. Yi, et al.. Optimized beryllium target design for indirectly driven inertial confinement fusion experiments on the national ignition facility[J]. Physics of Plasmas, 2014, 21(2): 022701.
  • 4Oertel J A, Aragonez R, Archuleta T, et al.. Gated X-ray detector for the national ignition facility[J]. Review of Scientific Instruments, 2006, 77(10): 10E308.
  • 5Bell P M, Bradley D K, Kilkenny J D, et al.. Radiation hardening of gated X-ray imagers for the national ignition facility [J]. Review of Scientific Instruments, 2010, 81(10): 10E540.
  • 6Xiong Gang, Hu Zhimin, Li Hang, et al.. One-dimensional space resolving flat-field holographic grating soft X-ray framing camera spectrograph for laser plasma diagnostics[J]. Review of Scientific Instruments, 2011, 82(4): 043109.
  • 7Cai Houzhi, Liu Jinyuan, Niu Lihong, et al.. Non-gain microchannel plate gated framing camera[J]. Review of Scientific Instruments, 2011, 82(5): 056102.
  • 8蔡厚智,刘进元,彭翔,牛丽红,彭文达,顾礼.X射线皮秒分幅相机的研制[J].深圳大学学报(理工版),2012,29(2):123-128. 被引量:7
  • 9白雁力,张驰,张敬金.X射线分幅相机发展研究[J].电视技术,2013,37(19):254-257. 被引量:4
  • 10白雁力,龙井华,蔡厚智,雷云飞,张又文,李仕潭,刘进元.短磁聚焦分幅变像管空间分辨率的模拟与测试[J].深圳大学学报(理工版),2015,32(2):178-182. 被引量:8

二级参考文献61